高精度半導体定温直列蒸発器の冷凍効果
The high-precision semiconductor constant temperature series of different models of the equipment, the choice of evaporation is also different, then, what effect does the heat exchanger have on the high-precision semiconductor constant temperature series?
Depending on the model, the choice of evaporator is different, such as box-type high-precision semiconductor constant temperature series, using water tank coil evaporator; open high-precision semiconductor constant temperature series and screw high-precision semiconductor constant temperature series, Shell-and-tube evaporators are available; for acid-base high-precision semiconductor constant temperature series, titanium tube evaporators or stainless steel plate exchangers are available. A chiller can have a variety of options, of course, can be customized according to user needs.

The factors affecting the evaporation temperature of industrial high-precision semiconductor constant temperature series are as follows:
The evaporator pipe is oily. Under normal conditions, since the lubricating oil and the refrigerant are mutually soluble, no oil film is formed on the surface of the heat exchanger, and the oil film thermal resistance may be disregarded. However, in the case of additional lubricating oil, the same label as the original one must be used. Lubricating oil to prevent the formation of oil film.
The air filter is clogged and the filter must be replaced regularly to ensure the required circulation air volume. Dry filter plugging: In order to ensure the normal circulation of the cooling enthalpy, the refrigeration system must be kept clean and dry. If the system has impurities, the drying filter will be blocked, the system will be difficult to supply liquid, and the cooling effect will be affected. Too little refrigerant, additional refrigerant.
The temperature condition of the high-precision semiconductor constant temperature series evaporator. Under normal conditions, the outer surface of the evaporator is very cold, and the condensation water drops continuously, the temperature of the inlet and outlet air is large, abnormal, the surface of the evaporator is not too cool, dew Not much, or no condensation, you can hear the sound of the refrigerant flow is very loud, the temperature difference between the inlet and outlet is small. The reason is that the refrigerant amount is insufficient, or the expansion valve opening degree is small.
The quality requirements of high-precision semiconductor constant temperature series heat exchangers are very high. When users choose, they can also look at the quality and brand of their heat exchangers. It is recommended to choose a better one.
関連推奨品
-
どのような電池パック試験室が実験室に適合しますか?
760実験室でのバッテリーパック試験室の使用は、試験結果の正確性と安全性を保証するために、一連の厳しい要件を満たす必要があります。これらの要件には主に以下の側面が含まれます:温度コン...
詳細を見る -
Low temperature chilled lubricant selection considerations
1256When you use a cryogenic chilled, you definitely want to know about all aspects of the cryocooler. But one of the things that needs everyone's attention is that the type of lubricant for the chilled is chosen because there are many influencing fac...
詳細を見る -
なぜ冷却水循環装置は水循環が中心なのですか?
914冷却水循環装置は、水を冷却に利用する方法である。外気温の上昇に伴い、多くの企業でも循環水の利用が増えている。循環水の補助は、水冷を目的とした...
詳細を見る -
低温冷凍機シリーズのご紹介-低温プロセス冷凍機
925熱音響冷凍技術は、幅広い応用が期待できる新しい冷凍方法である。過去30年間における冷凍・低温技術の大きな進歩のひとつである。熱音響エンジンは、熱音響効果を利用して...
詳細を見る