The Refrigeration Principle of Heating Cooling Circulator
Heating cooling circulator is the use of limited refrigerant in the closed refrigeration system, repeatedly refrigerant compression, condensation, expansion, evaporation, constantly in the evaporator heat absorption vaporization, cooling.
について heating cooling circulator is the circulation process that moves the heat from the low temperature object (such as the cold storage) to the high temperature object through the refrigerant, so as to cool the object below the ambient temperature and maintain the low temperature. This process is realized by the refrigeration device
The important parameter of the heating and cooling circulator is the coefficient of refrigeration, also known as the performance coefficient of the refrigeration unit, represented by the symbol COP. At a given ambient temperature, the lower the temperature of the cold storage, the smaller the coefficient of refrigeration.
The whole liquid cycle is closed, with the expansion vessel, the expansion vessel and the liquid cycle are insulated, do not participate in the liquid cycle, just mechanically connected, temperature the medium in the expansion vessel is less than 60 degrees no matter the liquid cycle temperature is high or low.
The whole liquid circulation is a closed system. At low temperature, there is no water vapor absorption, and at high temperature, there is no oil mist generation. Thermal oil has a wide range of operating temperature. No mechanical or electronic valves are used throughout the system.
Analysis of refrigeration principle
01.Compressed air refrigeration cycle
Due to the air constant temperature heating and constant temperature exhaust heat is not easy to achieve, so it can not run by the reverse cycle. In the compressed air refrigeration cycle, two constant pressure processes are used to replace the two constant temperature processes of the reverse cycle, so it can be regarded as the reverse cycle. In engineering applications, the compressor may be either piston or impeller type.
02.Compressed vapor refrigeration cycle
The reverse refrigeration cycle of compressed steam can be achieved in theory, but it will appear that the dry state is too low, which is not a positive factor for two-phase material compression. In order to avoid adverse factors, increase the refrigeration efficiency and simplify the equipment, in practical applications often use throttle valve (or expansion valve) to replace the expander.
関連推奨品
-
産業用冷凍機の冷凍特性とは?
1176入口と出口の水の温度差が大きい場合は、大きな外部タンクを使用して冷水を貯蔵する。この場合、冷却水はクーラーから直接供給されることはない。クーラーの外側の奥深く...
詳細を見る -
超低温循環式冷凍機の紹介
1141The performances of ultra low temperature recirculating chillers are different because of their different compressors. Compared with piston compressor, the structure of screw-type compressor tends to be more precise, so when users need to select u...
詳細を見る -
The Installation Requirement of the Industrial Chiller
993(1) The chiller power supply adopts three-phase four-wire, power supply line (R, S, T) connected with power supply fire line, (N) zero line, (G) ground line.,
詳細を見る -
Directly at the exhibition | Shanghai Automotive Testing Expo
1270Application vehicle type:1. Hybrid electric vehicle; 2. Pure electric vehicle; 3. Hydrogen engine car; 4. Fuel cell electric vehicle; 5. Extended-range electric vehicle; 6. Other new energy vehicles;Application automotive field:It is specially d...
詳細を見る