原子炉の自動温度制御システムの不具合を解決するには?
原子炉の自動温度制御システムの性能は非常に重要です。起動できないような故障に遭遇したら、できるだけ早くそれを解決しなければならない。

If you encounter a compressor startup failure in the automatic temperature control system of the reactor, first check whether the power supply is normal. The power supply voltage should not exceed or be lower than the rated voltage of the unit. Commonly used voltages are 3-phase 380V and single-phase 220V. When the voltage is too low or too high, the automatic temperature control system of the reactor cannot be started. For compressor units with a water system, carefully check whether there is water in the cooling water system and the chilled water system, whether the water pressure is normal, and whether the cooling water and chilled water pipeline systems are unblocked.
Check whether the various pressure gauges, thermometers, flow meters, solenoid valves, relays, and energy regulating valves of the automatic temperature control system of the industrial reactor are in good condition. Check the transmission device, if it is driven by a belt, whether its various protective devices are completely reliable, and whether all kinds of wrong equipment and protective equipment are complete and effective. Check whether the various valves of the high-pressure system and low-pressure system of the industrial reactor automatic temperature control system are in the correct switching state when starting or running.
Check the crankcase lubricant. The oil level should not be lower than or higher than the indicated oil level. If the lubricating oil is insufficient, add enough lubricating oil of the same specification and model. Check whether the refrigerant system of the automatic temperature control system of the industrial reactor is leaking, and whether the lubricating oil system is leaking. Check whether the liquid level of the liquid storage tank is normal, and the liquid level should be kept between one-third and two-thirds.
Next, follow the steps to troubleshoot, first check the main circuit. For example, whether the power supply has electricity, whether the voltage is normal, whether the fuse has been blown due to starting overload, whether the air switch is tripped, whether the switch contacts are good, and whether the power supply lacks phase.

Observe the voltmeter and ammeter when starting. When the automatic temperature control system of the reactor is not equipped with an ammeter or voltmeter, a multimeter or a tester can be used to check the power supply. When the power supply voltage is too low, the compressor cannot be started. For piston refrigeration compressors, whether the large-end bearing bushes and the curved sleeves of the connecting rods hold shafts. These can be caused by the excessively high exhaust temperature during the previous operation, or it can be caused by the coking of the lubricating oil, which makes the cylinder and the piston stick together, making the compressor unable to start. Check differential pressure relay and high and low voltage relay. When the oil pressure of the compressor is abnormal, the compressor can be stopped.
At the same time, when the compressor discharge pressure and suction pressure are abnormal, neither can start or the compressor will stop running soon after it has started. Check whether the amount of chilled water, cooling water, and water temperature are normal. If the water volume is small and the water temperature is high, it will cause the condensing pressure to rise sharply and the evaporation temperature to drop rapidly. Due to the action of the unit protection facilities, the unit often shuts down quickly. Check whether the relevant solenoid valves and regulating valves are out of order, and whether they are opened or closed as required. Check whether there is a leakage of working fluid in the temperature sensing bag of the temperature relay, or the adjustment is wrong.
関連推奨品
-
ガラスリアクターの選び方温度制御システムの合わせ方は?
965ガラス釜リアクターは多くの実験設備に必要であり、一般的に温度制御システムと共に使用される。化学と製薬の分野では、輸入ガラス反応釜は基本的に必需品であり、冷凍熱...
詳細を見る -
Vocs吸着装置冷凍温度制御説明書
1090With the continuous improvement of environmental protection requirements, each factory has also concentrated the processing of vocs gas generated in production. LNEYA vocs adsorption equipment can process various vocs gases. So how much do you kno...
詳細を見る -
低温チラーサーキュレーター用スクリューコンプレッサー冷凍機解説
1203Because of the different compressors, the performance of the low temperature chiller circulators is also different. Screw compressors are different from piston compressors, and the structure is more precise. Therefore, if users need to choose the ...
詳細を見る -
Description of the development of the wafer chip test system
959With the development of the semiconductor industry, the wafer chip test machine has also made great progress. How much do you know about the development of the wafer chip test machine? The integrated circuit industry has gradually emerged since th...
詳細を見る