How to solve the phenomenon of ultra-low temperature freezer card cylinder?
If the ultra-low temperature freezer room fails during operation, it needs to be solved in time. If it is similar to the related phenomenon, it may be that the frozen oil does not come up, and the operator needs to solve it in time.
Ultra-low temperature freezer compressor compressor card cylinder processing method is more, increasing the capacitance is one of the common methods, simply speaking, the original capacitor and a capacitor or a large point of capacitance to increase the starting torque to make the compressor easier Run it up, pay attention: the compressor will shut down immediately after two or three seconds.
Ultra-low temperature freezer compressor card cylinder tapping method, generally choose wooden hammer or select available objects in place. The hammer hits the three solder joints on the body when the press is started. But pay attention, you can’t knock deformation. Gently tap the compressor casing to slightly loosen the stuck part, sometimes start the operation or increase the power supply voltage by 10%, and start the impact multiple times. This method can solve the problem of insufficient lubrication of the card cylinder. The compressor of the chiller is particularly effective. The ultra-low temperature freezer compressor card cylinder can also adopt the strong lifting method, connect a plug, L is directly connected to the C terminal, N is connected to the M terminal, and the other is connected to the branch line N1. The power is turned on to let the N1 touch the starting end of the compressor. .
The pneumatic shock method can be used to separate the compressor separately, and the compressor is supplied with a reaction force of 0.1 MPA from the high pressure pipe. The loose shaft mechanism is loosened. Rinse for 5 minutes. Then use the above method. Usually, there is a scale inside the compressor, or a card cylinder caused by dirty things. The above does not work. The compressor is removed and the oil is poured out. Add kerosene, then pour it out, once in a row, the purpose is to clean the dirty things inside. After washing, put the compressor upside down for 12 hours, pour the kerosene and volatilize it. Then add the frozen oil, pick up the compressor and then a few times on the ground to loosen the parts. Then use the above method to start.
Regardless of the failure of the ultra-low temperature freezer, the user needs to solve the problem in a timely and effective manner. If another unknown fault occurs, contact the manufacturer’s technical personnel for resolution.

関連推奨品
-
Energy storage system requirements for temperature-controlled liquid-cooled unit
1454Energy storage system: It needs to meet the discharge demand for a long time. It is suitable for energy storage on the side of new energy generation, arbitrage of peak-valley price difference on the user side, etc. The future trend is that...
詳細を見る -
実験室用晶析温度制御冷却・加熱システム
861実験室での晶析プロセスにおいて、温度制御された冷却・加熱システムは、晶析液の温度を正確に制御するために使用される重要なコンポーネントである。
詳細を見る -
蒸しシステム温度制御の安全要件
1148The steaming system temperature control is one of the low temperature refrigerators designed and produced by Wuxi Guanya LNEYA. The temperature range is from -5 °C to -150 °C. The secondary subcooling technology is adopted, the refrigeration is ra...
詳細を見る -
循環水冷却装置の冷媒は何ですか?
995業界によって、循環水冷却装置に求められる冷凍温度は異なるため、選択される冷媒も異なります。循環式水冷装置を選ぶ際には、冷媒についての明確な理解も必要です。
詳細を見る