The reason why the semiconductor small thermostat is blocked by refrigeration
The small semiconductor small-scale thermostat ice jam is mainly caused by the excessive moisture contained in the refrigeration system. With the continuous circulation of the refrigerant, the moisture in the refrigeration system gradually collects at the capillary outlet, in view of the relatively low temperature at the capillary outlet, the water It forms ice and gradually increases. When it reaches the necessary level, the capillary is completely blocked, the refrigerant does not recur, and the semiconductor small thermostat does not cool.
The main reason for the moisture in the small semiconductor small-scale thermostat refrigeration system is that the electromechanical insulation paper in the compressor contains water, which is the main source of moisture in the system. In addition, the residual moisture of the components of the refrigeration system and the combined pipelines due to insufficient drying; the refrigeration oil and the refrigerant contain more than the allowable amount of moisture; during the installation or maintenance process, the pipeline is in a state of development for a long time, causing moisture in the air to be Inhaled by electromechanical insulation paper and refrigerating machine oil.

In view of the fact that the above causes the water content of the refrigeration system to exceed the allowable amount of the refrigeration system, ice plugging occurs. On the one hand, ice plugs become refrigerants, and semiconductor small thermostats do not normally cool; on the other hand, water also reacts with refrigerants, synthesizes hydrochloric acid and hydrogen fluoride, and turns into corrosion of metal pipes and components. It will cause insulation damage of the electromechanical winding, and at the same time it will become the smell of the refrigerating machine oil, and the compressor will be smooth, so the water in the system is forced to operate at a relatively low limit.
The semiconductor small thermostat should try to avoid the blockage of its refrigeration system. If there is a blockage, it is also necessary to contact the technician to solve it in time.
関連推奨品
-
工場ボイラーの操作に関する誤解
893ボイラーは工場ではごく一般的な設備だ。LNEYAシャオビアンは、多くの人がボイラーについて誤解していると皆に言う。誤解1 蒸気圧は高ければ高いほど良い。ボイラーの蒸気圧の選択は主に...
詳細を見る -
蓄電池試験解析システムにおける電池ボックスの静的強度解析
1332新エネルギー車のバッテリーボックスは、電気自動車の中核部品の一つである。高強度、高剛性、高セキュリティ、高軽量のバッテリーボックスを設計することは、電気自動車の発展にとって非常に重要である。高...
詳細を見る -
RFチップ高温・低温自動試験機制御システムの説明
1324半導体チップ産業の継続的な発展に基づいて、LNEYA RFチップ高温および低温自動試験機も消費者に推進されています。そこで、RFチップ高温・低温自動試験機について何を知っていますか?
詳細を見る -
実験室プロセス温度制御サイクルシステム「チラー」の取扱説明書
1077実験室プロセス温度制御循環システムチラーの熱媒体は、油と水を使用します。配管内を強制的に循環させる熱媒体(熱媒体油または水)を電気加熱で加熱する。
詳細を見る