Rapid temperature change test chamber temperature control instructions
The selection of the humidity range of the rapid temperature change test chamber should be noted that the corresponding temperature range should be indicated after the humidity index or the dew point temperature should be given. Because relative humidity is directly related to temperature, for the same moisture content, the higher the temperature, the lower the relative humidity. To achieve high temperature and high humidity, it is only necessary to spray water vapor or atomized water droplets into the air of the cabinet to humidify. Low temperature and low humidity are relatively difficult to control, because the moisture content at this time is very low, and sometimes it is much lower than the moisture content in the atmosphere, and it is necessary to dehumidify the air flowing in the tank to make the air dry.
The common rapid temperature change test chamber generally refers to a constant rapid temperature change test chamber, which is controlled by setting a target temperature and the test chamber has the ability to automatically thermostat to the target temperature point. The control method of the constant temperature and humidity test chamber is similar. Set a target temperature and humidity point. The test chamber has the ability to automatically adjust the temperature to the target temperature and humidity point. The high and low temperature alternating test chamber has the program of setting one or more high and low temperature changes and circulations. The test chamber has the ability to complete the test process according to the preset curve, and can control the temperature rise within the range of heating and cooling rate capability. The rate of temperature drop, that is, the temperature rise and temperature drop rate can be controlled according to the slope of the set curve.

Similarly, the high and low temperature alternating heat and humidity test chamber also has a preset temperature and humidity curve, and the ability to control according to presets. Of course, the alternating test chambers all have the function of a constant test chamber, but the manufacturing cost of the alternating test chamber is higher, because the alternating test chamber needs to be equipped with a curve automatic recording device, a program control device, and the test chamber must be solved in the working chamber. When the temperature is high, the refrigerator is turned on. Therefore, the price of the alternating test chamber is generally 20% higher than the price of the constant test chamber. Therefore, we should be realistic and take the test method as the starting point, choose a constant test box or an alternating test chamber.
Different rapid temperature change test chamber manufacturers have different quality, so users need to understand the rapid temperature change test chamber and make more detailed choices.
関連推奨品
-
グリコールチラーシステムを長持ちさせるには?
1003工業用グリコールチラーを長寿命化するために、以下の点にご注意ください:1.1.自動車グレードの不凍液は慎重に使用してください自動車グレードの不凍液や不適格な不凍液は使用しないでください。なぜなら、このグリ...
詳細を見る -
工業用冷凍庫トップ10のメンテナンス
1200私たちがトップ10ブランドの工業用冷凍庫を選び、購入するとき、いくつかの必要なニーズに加えて、我々はまた、工業用冷凍庫の使用とメンテナンスに注意を払う必要があります。
詳細を見る -
What are the maintenance of glycol chillers in daily operation?
1203In the daily operation of the glycol chiller, if the maintenance is not in place, the cooling effect will be reduced. Therefore, in order to improve the operating efficiency, we recommend that you carry out the necessary daily maintenance. Refrig...
詳細を見る -
リチウム電池試験用冷却・加熱循環装置使用上の注意事項
995専門的な実験補助器具として、リチウム電池試験用冷却加熱循環装置は、冷源と熱源の循環供給端であり、動作範囲が広い。リチウム電池試験用冷却・加熱循環装置は、冷熱源と熱源の循環供給端であり、使用範囲が広い。
詳細を見る