大型急速冷凍コンプレッサーの冷却問題にどう対処するか?
大型急速冷凍機のコンプレッサーには多くの種類があり、機種によってコンプレッサーのメーカーや型式も異なる。コンプレッサーの温度が高くなりすぎると、故障の原因になるため、冷却も重要です。
In the operation of large-scale quick-freezer compressors, cooling is an indispensable part. The compressor should always pay attention to the cooling water. Once the water is cut off, it must be stopped immediately for inspection. Components that require water to be cooled by the compressor include cylinders, intercoolers, compressor aftercoolers, and oil coolers.
For large freezer cylinders and intercoolers, one of the purposes of cooling is to reduce the exhaust temperature so that the exhaust temperature does not exceed the allowable range. It can be seen that after the large-scale quick-freezer compressor is shut off, the cylinder and the intercooler are not cooled, and the exhaust temperature of the compressor rises sharply. This not only causes the lubricating oil in the cylinder to lose lubrication performance, but also causes the moving parts to wear rapidly, and the lubricating oil is decomposed, and the volatile components in the oil are mixed with the air, causing accidents such as burning and explosion.
For large-scale quick-freezer compressor oil coolers, the water loss of the Wuxi Guanya LNEYA compressor will result in poor cooling of the lubricating oil and an increase in the temperature of the compressor lubricating oil. In this way, the viscosity of the lubricating oil is lowered, the lubricating performance is deteriorated, the wear of the moving parts is intensified, the life of the machine is reduced, the power consumption is increased, and the lubricating oil is decomposed, and the volatile components in the oil are mixed into the air, causing an accident.
Overheating of the compressor will affect the operation of the large-scale quick-freezer, so it is recommended to do the cooling work in order to run smoothly.

関連推奨品
-
Description of power consumption in LNEYA large refrigeration unit
1266In the process of operation, the cooling capacity and working conditions will affect the power consumption of the entire large refrigeration unit, but in order to avoid unnecessary power consumption, we need to understand the other power consumpti...
詳細を見る -
ZLF/SRシリーズ原子炉温度調節装置の運転上の注意事項
1130反応釜の温度制御設備はPID制御方式を採用し、機械全体の温度制御精度を大幅に向上させる。冷却と加熱のマイクロコンピューターは自動的に切り替わり、作業一致...
詳細を見る -
完全密閉式冷凍・暖房機の運転特性の説明
1402石油、化学、製薬業界では、完全密閉式の冷凍・暖房一体型機械が多くの企業で必要とされている。しかし、ユーザーが選択する際には、その運転特性を理解する必要がある。
詳細を見る -
40GW極低温冷凍機の機種選定と分類の説明
1145無錫官哉40GW極低温冷凍機は、企業や業種が違えば、機種選定も異なります。ですから、40GW極低温冷凍機の選択のニーズを明確に理解する方がよいでしょう。
詳細を見る