Precautions for installing reactor refrigeration and heating circulator
The reactor refrigeration and heating cycle equipment can achieve high temperature of 200℃ and low temperature constant temperature test of -120℃, providing users with a field source with controlled thermal cooling and constant temperature. It can also be used as a heat source or cold source for direct heating, cooling, auxiliary heating, and auxiliary refrigeration. Source, temperature control within the full range, used in diffusion process control of semiconductor diffusion furnaces, constant temperature control or external circulation applications in reactors, fully automatic synthesis instruments, extraction and condensation devices.
Working principle of reactor refrigeration and heating cycle equipment:
The reactor refrigeration and heating cycle equipment uses coolant as the heat transfer medium to transport the heat generated by other instruments or equipment that need to be cooled, and sends the heat to the outside of the equipment through the refrigeration system to ensure that the equipment works within the normal temperature range. The device and the instrument rely on the pressure of the pump in the device to form a closed medium circulation, and the temperature sensor is used to detect the temperature of the medium to realize the control of the cooler.
Installation environment of reactor refrigeration and heating cycle equipment:
The reactor refrigeration and heating cycle equipment has a semi-closed cycle. At high temperatures, no oil mist evaporates, and the thermal oil will not be oxidized and browned. At low temperatures, it will not absorb water vapor in the air, extending the life of the thermal oil. Reactor refrigeration and heating cycle equipment should be installed in a laboratory with a good environment; it should be installed on a well-ventilated, dust-free, stable floor or experimental table to avoid droplets, excess vapor, and possible inflow, stagnation, and leakage of flammable gases. Avoid places that can generate high-frequency equipment (high-frequency welding machines, etc.).
When the reactor refrigeration and heating cycle equipment avoids frequent use of acidic solutions and frequent use of special sprayers (containing sulfides, etc.), from the perspective of convenience and safety during maintenance and installation, try to ensure that there is a gap between the indoor unit and obstacles. have enough space.
Follow the instructions when installing:
The use of 300°C refrigeration and heating cycle equipment is inseparable from its standardized operation. When selling, there will be corresponding instructions for use when the equipment leaves the factory. Users can understand it in advance when using it.
The reactor refrigeration and heating cycle equipment is simple to install and operate, and does not require professional operation. The operator can be operated with simple training or by following the instructions; the heating method is circulating heating, so there is no loss of the medium; no need Annual review.
要約する
The reactor refrigeration and heating cycle equipment is heated evenly, and the temperature adjustment adopts PID self-tuning intelligent control. The temperature control accuracy is ±1°C, which can meet the strict requirements of high process standards. Closed cycle heating, small heat loss, wide range of use.
SUNDI Z 周波数変換シリーズ
WHATSAPP WECHAT 超高温冷却技術は、300℃の高温から直接冷却することができます[なぜなら膨張の熱媒体のみ...
スンディ -10℃~150
完全に封じられたシステム、単一の媒体は冷凍および暖房 -120~350℃ ±0.5℃ AC 380V 50HZ 8kW 最高を完了します 超高温冷却の技術は高温から直接冷却できます。
スンディ -80℃~250
動作温度範囲:-120°C~+350°C ●これまでにない性能 ●インテリジェントな温度制御 ●プロセスの安定性と再現性を最大化 ●アドッププレート式熱交換器、パイプライン加熱、高速...
SUNDI-320/320W
完全に封じられたシステム、単一の媒体は冷凍および暖房 -120~350℃±0.5℃を完了します 超高温冷却の技術は 300℃高温から直接冷却できます。超...
スンディ -25℃〜200
完全に密閉されたシステム、単一の媒体は冷凍および暖房を完了する -120~350℃ ±0.5℃ ● -120°Cから+350°Cまで働く温度 ●以前達成できなかった性能 ●理性的な温度調整...
スンディ -25℃〜300
動作温度範囲:-120°C~+350°C ●これまでにない性能 ●インテリジェントな温度制御 ●プロセスの安定性と再現性を最大化 ●アドッププレート式熱交換器、パイプライン加熱、高速...
スンディ -45℃〜250
動作温度範囲:-120°C~+350°C ●これまでにない性能 ●インテリジェントな温度制御 ●プロセスの安定性と再現性を最大化 ●アドッププレート式熱交換器、パイプライン加熱、高速...
スンディ -60℃~250
超高温冷却技術は、300℃の高温から直接冷却することができる[膨張室内の熱媒体のみが酸化物と接触するため]。
ロード...
已经是到最后一篇内容了!」。
VIDEO
関連推奨品
-
スンディ -25℃〜300
2279動作温度範囲:-120°C~+350°C ●これまでにない性能 ●インテリジェントな温度制御 ●プロセスの安定性と再現性を最大化 ●アドッププレート式熱交換器、パイプライン加熱、高速...
詳細を見る -
0℃~+100℃(1&6)
2183車両品質テスト用温度シミュレーション:バッテリー寿命テスト、燃料インジェクター/モーターテストベンチ、エアバッグテスト、コンポーネントテストベンチなど。また、外部環境条件をシミュレートすることができます。
詳細を見る -
KRY -40℃~+100℃ (1~6)
2481コンポーネントは、冷却され、テストのためのエチレングリコール水溶液を介して内部加熱される -40 ° C〜100 ° C(150 ° Cに拡張可能)電源バッテリ充電管理のために、精密な...
詳細を見る -
HR -25℃~200
2248The cooler is a very important part of the screw air compressor. The main function is to cool the lubricating oil of air compressor and the compressed air. If it's blocked, then the temperature will go up. A...
詳細を見る