小型高温および低温衝撃試験チャンバー容積選択手順書
When the test product (components, components, components or complete machine) is placed in a small high and low temperature impact test chamber for testing, in order to ensure that the atmosphere around the test product can meet the environmental test conditions specified in the test specification, the small high and low temperature impact test There should be some points of attention between the working size of the box and the outer dimensions of the tested product. The volume of the tested product should not exceed (20~35)% of the effective working space of the test box. It is recommended to use no more than 10% for products that generate heat during the test. The ratio of the windward cross-sectional area of the test product to the total area of the test chamber on the section is not more than (35 to 50)%. The distance of the outer surface of the test product from the wall of the test chamber is at least 100 to 150 mm.
After the test piece is placed in the box, the smooth passage is occupied, and the narrowing of the passage will result in an increase in the flow rate of the air flow. Accelerate the heat exchange between the gas stream and the test piece. This is inconsistent with the reproduction of environmental conditions, because in the relevant standards, the temperature flow around the test specimens in the test chamber should not exceed 1.7 m/s, so as to prevent the test specimens and the surrounding atmosphere from being produced. Heat transfer. If the volume of the test piece or the wind-breaking area is increased without restriction in the test, the airflow speed will increase beyond the wind speed specified in the test standard during the actual test, and the validity of the test results will be suspected.

The accuracy index of the environmental parameters in the working chamber of the small high and low temperature impact test chamber is the result of the test under no-load condition. Once the test piece is placed, the uniformity of the environmental parameters in the working chamber of the test box will be affected. The greater the space occupied, the more serious this effect will be.
According to the principle of heat conduction, the temperature of the gas flow near the tank wall is usually 2 to 3 °C from the center temperature of the flow field, and may reach 5 °C at the upper and lower limits of the high and low temperature. The temperature of the tank wall is different from the temperature of the flow field near the tank wall by 2~3 °C (depending on the structure and material of the tank wall). The greater the difference between the test temperature and the external atmospheric environment, the greater the above temperature difference, therefore, the distance from the tank wall The space within the distance (100 to 150 mm) is an unusable space.
The volume selection instructions above the small high and low temperature impact test chamber do not know that you understand it. I believe that users can better select the equipment after reading these.
関連推奨品
-
マイナス30℃の低温管理機器の日常点検の注意点
1075マイナス30℃の低温制御機器は冷凍機、あるいは冷凍ユニットとも呼ばれる。冷凍機との違いは温度範囲である。産業界でよく使われる低温装置である。
詳細を見る -
High and low temperature hot and cold water cooling machine for battery motor test
1064LNEYA high and low temperature cold and heat integrated water cooler is used in battery thermal management of new energy electric vehicles. The following is the relevant principle applied in thermal management.The high and low temperature cold and...
詳細を見る -
Recommendations for the use of integrated chip test equipment in the test process
1045From the perspective of the entire semiconductor industry, semiconductors can be divided into R & D, production, and application stages. At different stages, the role of testing is different. Control of test equipment, including test machines,...
詳細を見る -
スクリューチラー工場の冷凍機油交換に際しての注意事項
1075The refrigerant oil in the screw chiller factory needs regular inspection and replacement. We all know that different grades of refrigerant oil cannot be mixed together, otherwise it will cause abnormal or strike conditions of the screw chiller fa...
詳細を見る