High precision semiconductor incubator maintenance instructions
The high-precision semiconductor incubator is in the state of the evaporator as a gas refrigerant; after the adiabatic shrinkage of the shrinking machine, it becomes a high-temperature and high-pressure state, and the contracted gas refrigerant is condensed in the condenser by equal pressure, and is converted by condensation. The liquid refrigerant is expanded into a low pressure through a throttle valve to become a gas-liquid mixture. The liquid refrigerant at low temperature and low pressure absorbs the heat of the cold material in the evaporator, and changes from the head to the gaseous refrigerant. The gaseous refrigerant enters the shrinking machine through the pipe and starts the new cycle. This is the high-precision semiconductor thermostat reincarnation. Four processes.
The high-precision semiconductor thermostat sealing part is nursed back. Since the assembled high-precision semiconductor thermostat is made up of several pieces of insulation board, there is a necessary gap between the boards. In the construction, such gaps are sealed with sealant, in order to avoid air. And the water comes in, so in the use of some parts of the seal is not repaired in real time.
High-precision semiconductor incubator ground nursed back, usually the surface of the small-assembled high-precision semiconductor incubator uses thermal insulation board. When using high-precision semiconductor incubator, in order to avoid a large amount of ice and water on the ground, if there is ice, it must not be processed. Use hard objects to knock and damage the ground.

High-precision semiconductor incubators are used after assembly or long-term deactivation. The rate of cooling should be appropriate: daily operation at 8-10 °C is appropriate, and should be retained for a period of time at 0 °C.
High-precision semiconductor thermostat library board nursery, pay attention to the use should pay attention to the collision and scratching of the hard object on the library, in view of the possibility of becoming the concave and rust of the library board, it will seriously reduce the surface insulation function of the library.
The maintenance of high-precision semiconductor incubators is inseparable from the careful operation of our operators, so we should be kind to our equipment in daily operations, not too rough.
関連推奨品
-
API China [A1A20-2]は新しいお客様、古いお客様を歓迎いたします!
1241APIチャイナは、中国の産業分野における長年にわたる大規模な展示会として、医薬品産業の発展と成長を促進し、見守ってきた。
詳細を見る -
小型高圧反応釜冷凍加熱温度制御システム
1006The miniature high-pressure reaction kettle refrigeration heating temperature control system is designed with a gas feed unit, a liquid feed unit, a reaction unit and a collection unit. The raw material gas and raw material liquid are mixed and pr...
詳細を見る -
Description of power consumption in LNEYA large refrigeration unit
1267In the process of operation, the cooling capacity and working conditions will affect the power consumption of the entire large refrigeration unit, but in order to avoid unnecessary power consumption, we need to understand the other power consumpti...
詳細を見る -
What are the characteristics and application scope of cryogenic refrigeration circulators?
1156Specializing in the development and production of low-temperature refrigeration circulators, the refrigeration temperature range is from -120 degrees to -30 degrees. Today, let us take a look at the characteristics of low-temperature refrigeration...
詳細を見る