How to deal with organic waste gas treatment refrigerant leakage?
In the process of organic waste gas treatment, if it is found that the refrigerant leaks, it is recommended to treat it in time. LNEYA organic waste gas treatment professional manufacturer then analyzes the knowledge of organic waste gas treatment refrigerant leakage.
Organic waste gas treatment VOCS gas single material or multi-material condensation recovery, the main treatment gases are: hydrocarbons such as gasoline, crude oil, fuel oil, kerosene, diesel, heavy oil, mixed hydrocarbons; aromatics: benzene, toluene, xylene, Styrene, naphtha, etc.; alcohols, ethers, ketones, esters, etc., in the event of a situation, we must now fill the leak or treatment of the refrigerant leakage, then replace the desiccant, re-vacuum treatment, Fill the appropriate refrigerant. When you find that the leaking refrigerant is partially immersed in water, stop the chiller and quickly remove the water from the tank to prevent the compressor from drawing water into the system for more serious damage.

So, what should be done if the organic waste gas treatment refrigerant is found to be insufficient? Organic waste gas treatment failure phenomenon: the whole vehicle refrigeration effect is poor, the air outlet air is only cool, and the manifold pressure gauge check finds that the high pressure is cut and the low pressure side pressure is low (when the compressor speed is 2000/mim, the ambient temperature is about 35C). The low pressure gauge index is lower than 1kg/CM square, the high pressure gauge index is lower than 10kg/CM square, and the bubble flow is visible from the sight glass.
This may be due to a refrigerant leak point in the refrigeration system, resulting in insufficient refrigerant. Treatment method Use an electronic leak detector to detect the leak point and carry out the replacement or replacement of parts. If the parts are not replaced, only the appropriate amount of refrigerant can be replenished; if the parts are replaced, the appropriate amount of refrigerating oil should be added as required, and the refrigerant should be added after the system is vacuumed.
The above is the relevant treatment of organic waste gas treatment refrigerant leakage. If the Wuxi LNEYA organic waste gas treatment equipment fails, it is recommended to solve it in time!
関連推奨品
-
Advantages of Industrial Chillers in Refrigeration
1144In recent years, the manufacturing industryhas entered a golden age. The market competition is fierce, and therequirements for product quality have been greatly improved. In fact, in theprocess of improving product quality, manufacturers oft...
詳細を見る -
What should I pay attention to when adding refrigerant to a water-cooled chiller
1149In our life, we believe that everyone isvery familiar with refrigeration. In the central air conditioning andindustrial production process cooling industry, small water-cooled chillers ismore common. This unit is composed of a compressor in the...
詳細を見る -
200L蒸留釜用チラー
785200L蒸留釜用チラーは二つの主要機能を同時に満たす必要があります:一つはメタノール蒸気を凝縮させること、もう一つは反応プロセス中の材料を冷却することです。...
詳細を見る -
高温・低温装置関連機器メンテナンス説明書
1112液体媒体は、高温・低温循環装置を使用する前に加える必要があります。液体媒体は一般的に95%アルコール以上を使用し、液体媒体は作業プレート20mmより低くすることはできません。高温・低温循環装置...
詳細を見る