流体伝熱温度制御システムの操作ミスを防ぐには?
During the operation of the fluid heat transfer temperature control system, if the fluid heat transfer temperature control system fails, the main reason is the operation error. So how do we avoid mistakes.

1. The operation of the fluid heat transfer temperature control system should pay attention to many aspects. First, operate the reactor strictly in accordance with the rules and regulations. Secondly, before operation, carefully check whether there is any abnormality. During normal operation, do not open the upper cover and touch the wiring terminals on the board to avoid electric shock.
2. Operation with pressure is strictly prohibited; in the process of pressure test, carefully observe the change of the pressure gauge, when the pressure test pressure is reached, close the valve switch immediately; the heating speed should not be too fast, and the pressure should be carried out slowly, especially the stirring speed, only allow Ramp up slowly.
3. When heated to a higher temperature, do not contact the kettle body to avoid burns; it should be cooled first after the experiment. Do not cool quickly to prevent damage caused by excessive temperature differential pressure. At the same time, unplug the power supply in time. At the same time, pay attention to maintenance after use, so as to have a better extended service life.
4. The main sealing port adopts A-type double-line sealing, and the other sealing points adopt the sealing form of line contact between arc surface and plane, arc surface and arc surface, relying on the high precision and smoothness of the contact surface to achieve good sealing. sealing effect.
5. The coupling is mainly composed of a pair of inner and outer magnetic rings with strong magnetic force, and there is a pressure-bearing spacer in the middle. The agitator is driven by a servo motor through a coupling. The purpose of controlling the stirring speed can be achieved by controlling the speed of the servo motor.
6. The outer body of the fluid heat transfer temperature control system is equipped with a barrel-shaped silicon carbide furnace core. The electric furnace wire is passed through the furnace core. connected.
7. The kettle body and the kettle cover are made of stainless steel. The kettle body is connected with the flange through threads. The kettle cover is a normal flat cover, and the two are fastened and connected by the main bolts and nuts evenly distributed in the circumferential direction.
8. The kettle cover of the fluid heat transfer temperature control system is equipped with pressure gauges, bursting membrane safety devices, vapor-liquid phase valves, temperature sensors, etc., which are convenient to know the reaction situation in the kettle at any time, adjust the medium ratio in the kettle, and ensure safe operation. .
9. The upper part of the spacer is equipped with a tachometer coil. When the integrated stirrer and the inner magnetic ring rotate, the tachometer coil generates an induced electromotive force, which corresponds to the stirring speed. The potential is transmitted to the tachometer to display the stirring speed. Rotating speed.
10. The bearing adopts stainless steel bearing or high-strength electrochemical graphite, which is resistant to wear and tear and has a long maintenance period.
11. A cooling water jacket is installed between the magnetic coupling and the kettle cover. When the operating temperature is high, cooling water should be passed through, and the magnetic steel temperature is too high to demagnetize.
関連推奨品
-
ラボ用ウォーターチラーのコロケーション要件
1172実験室用冷水機は、比較的先進的な冷凍保存装置で、血液ステーション、病院、健康、疫病予防システム、科学研究機関、電子産業、化学薬品、生物学、医療機器、医療機器などに適しています。
詳細を見る -
電気自動車用バッテリーの作動温度試験
1006電気自動車用パワーバッテリーの通常の作動温度範囲は-30~52℃、作動温度範囲は-46~66℃であり、既存のパワーバッテリーでは達成が難しい。局所的な温暖化対策は可能であるが、このような温度範囲は、既存のパワーバッテリーでは実現が困難である。
詳細を見る -
Why choose LNEYA’s reactor automatic temperature control equipment?
1304With the rapid development of pharmaceutical and chemical industry, the market demand for automatic temperature control equipment for reactors is expanding. The requirements for automatic temperature control equipment for reactors are also rising,...
詳細を見る -
チップテスト用温度シミュレーションシステムのメーカーが、なぜチップテストが必要なのかを分析する。
1052チップテスト温度シミュレーションシステムを実行するとき、ユーザーはチップテストを明確に理解する必要があります。そのため、LNEYAメーカーはチップテストに関する関連知識を分析し、より詳細な知識を提供します。機能...
詳細を見る