What Are The Characteristics Of The Reactor Heating System?
Wuxi Guanya LNEYA reactor heating system The liquid circulation of the whole system is closed, the system has an expansion vessel, the expansion vessel and the liquid circulation are adiabatic, do not participate in the liquid circulation, only the mechanical connection, regardless of the temperature of the liquid circulation is high temperature Or the medium in the low temperature expansion vessel is below 60 degrees. The whole liquid circulation is a closed system. There is no water vapor absorption at low temperature, no oil mist is generated at high temperature, and the heat transfer oil can have a wide working temperature. The same machine, the same heat medium can achieve -95 degrees to 200 degrees. temperature. Cooling capacity 1KW~ 80KW range No mechanical and electronic valves are used in the entire circulation system.

Features of Wuxi Guanya LNEYA reactor heating system:
1. Equipped with heating and cooling integrated container, the heat exchange area is large, the rate of heating and cooling is very fast, and the demand for heat transfer oil is relatively small. Continuous temperature rise and fall can be achieved. The refrigeration heat exchanger adopts a high-force plate heat exchanger, which has high heat exchange efficiency and small floor space. The whole cycle is closed, no oil mist is volatilized at high temperature, the heat transfer oil will not be oxidized and browned; the water vapor in the air will not be absorbed at low temperature; the life of the heat transfer oil is prolonged.
2. Temperature adaptive control, adaptive control system in the process of control technology (such as chemical reaction process), continuously adjust the PID parameters to give the process the best control temperature and response time, this process is through effective multi-directional The rate of temperature, temperature change and temperature change is measured. Features PT100 with correct external and internal circulation temperature probes.
3. With self-diagnosis function, freezer overload protection, high-pressure pressure switch, overload relay, thermal protection device and other safety functions, fully guarantee the safety of use;
4. Use CFC-free and HCFE refrigerants.
5. Precise control of the speed of chemical reactions.
6.Program function series. Nonlinear and linear temperature jump function. Each step of the program includes the control of the external loop program, which is controlled by the PLC controller computer.
7.Automatic diagnosis and system monitoring function series. Through the PLC touch screen controller, the computer implements monitoring and display detailed system information.
関連推奨品
-
LNEYA半導体冷凍ユニット共通故障説明書
1389If a high-voltage alarm occurs in the semiconductor refrigeration unit, it is necessary to check whether the external piping is blocked or dirty. Clean and remove in time. If it is an air-cooled semiconductor refrigeration device, it is necessary ...
詳細を見る -
Several elements of the operation of -20 degree industrial cryogenic chiller
1244-20 degree industrial cryogenic chiller is a refrigeration equipment that provides low temperature chilled water. It is often used in production enterprises, such as chemical companies, pharmaceutical companies and other production processes, to p...
詳細を見る -
Why is There Frost Phenomenon in the Low Temperature Chiller Circulator?
1096Many low temperature chiller circulators will frost when they are used, but there is no frost phenomenon in low temperature chiller circulators. So, what's the matter? Is it related to refrigeration?First of all, why does the low temperature chill...
詳細を見る -
Price Analysis of High Low Temperature Test Chambers
1048As the saying goes, “ You get what you've paid. ” The price of the high low temperature test chamber is related to the quality of its configuration. The technology of Wuxi LNEYA itself is priceless. In the test chamber industry, the high low tempe...
詳細を見る