精密冷凍機の騒音分析
Generally speaking, even the most sophisticated refrigerating equipment will also have some trouble when used for a long time. If the noises present in the 精密冷凍機 after prolonged use, I am sure that it appears some faults. So let’s go deeper to see where these noises are from.
The noise of compressor
The compressor is in the core position of the inner structure of the precision chiller. In general, compressors include screw and stroll, you can pick up one as what you need. Once the compressor has some noise, the first thing you should do is to check out if the expansive valve is open excessively; if so, you ought to adjust it. Next, you should see if the freezing medium is overmuch; if so, you had better remove the needless refrigerators.
The noise of water pump
It is attributable to the water quality mainly if the water pump has some noises. I suggest that water treatment should proceed according to the requirement of the chillers.
The accessories lack lubricant
The configuration of most of chillers is made of metal. Once the accessories are short of lubricant, the frictions can not be avoided, making some noises. Besides, you have to keep maintenance in daily life to reduce the rate of faults.
Oil starvation because of overload
You can find out whether the compressor is fuel elan when there are some noises. If it is, you can refuel it. To check if the compressor is overloaded will help you solve it in time.
Through the introduction of precision chillers, you must have a better understanding. If you are eager to further study, you can follow Guanya Refigeration Technology Co., Ltd.
関連推奨品
-
上海万博パビリオン【農薬展】ブース1G10 10.12-10.14に集合
1297展示会名:第20回全国農薬交流会・農薬製品展示場展示時間:10月12日(水)~14日(金):2020年10月12日~14日小間番号:1G10展示会の住所上海万博展覧館、
詳細を見る -
Different functions of reactor cooling and heating chiller on temperature
991The cooling and heating chiller of the reactor is a kind of refrigeration machine, because its main component uses a screw compressor, which can be called the low-temperature chiller of the reactor by its name, and is widely used in industrial pro...
詳細を見る -
Directly at the exhibition | Shanghai Automotive Testing Expo
1271Application vehicle type:1. Hybrid electric vehicle; 2. Pure electric vehicle; 3. Hydrogen engine car; 4. Fuel cell electric vehicle; 5. Extended-range electric vehicle; 6. Other new energy vehicles;Application automotive field:It is specially d...
詳細を見る -
縦型超低温冷蔵庫の伝熱効果低下の原因
975縦型超低温冷蔵庫の外側の霜層が厚すぎたり、過度に埃っぽかったりすると、機器の外部温度がほとんど0より低くなり、その結果、蒸発器の熱伝達効率が低下する可能性がある。
詳細を見る