The air-cooled chiller adopts the air cooling mode, which eliminates the essential cooling tower, cooling water pump and pipeline system of the cooling water system, avoids the condenser scaling and water pipe blockage in areas with poor water quality, and saves water resources. It is the most economical and simple machine for maintenance and repair in the current refrigeration equipment. The one-time investment of air-cooled chiller is slightly higher than that of water-cooled chiller, but the annual operation cost is lower than that of water-cooled chiller. The construction cost of machine room is the least among various cold and heat source systems, and the maintenance cost is about half of that of water-cooled chiller.

When the temperature of air or other fluid decreases, the pressure in the temperature sensing bag decreases. The valve port of the temperature control pilot valve is closed, and the refrigerant gas flow from the evaporator to the main regulating valve decreases. When the pressure at the top of the main piston is discharged into the suction pipe of the compressor, the main spring closes the main valve. In the air-cooled chiller system, when the evaporator pressure regulating valve is used to control the temperature, the temperature control pilot valve should be used to replace the pressure control pilot valve introduced earlier, so that the temperature of air or other fluids flowing through the evaporator can be accurately maintained at a predetermined value.
The evaporator is one of the four major components in the chiller system. The evaporator plays a role in heat dissipation in the chiller system. Connect the temperature control pilot valve with the joint of the outer pressure guide hole of the evaporator pressure regulating valve, and place the temperature sensing package of the pilot valve in the air flow or flowing medium to control its temperature. When the temperature of air or other medium increases, the pressure in the temperature sensing package increases, and the valve port of the temperature control pilot valve opens, so the evaporator pressure is transmitted to the space at the top of the main regulating valve piston through the outer pressure guide pipe, Press down the piston and open the main regulating valve. The evaporator pressure then drops to an appropriate value, which increases the temperature difference between air or other fluids and refrigerant, and improves the refrigeration capacity of the evaporator of the low-temperature chiller.
関連推奨品
-
循環式冷凍機の膨張弁の選定と設置
997膨張弁の選択は、再循環チラー冷凍システムの性能において重要な役割を果たす。膨張弁を正しく選択することで、冷凍機の性能を最大限に引き出すことができる。
詳細を見る -
なぜ冷却水循環装置は水循環が中心なのですか?
914冷却水循環装置は、水を冷却に利用する方法である。外気温の上昇に伴い、多くの企業でも循環水の利用が増えている。循環水の補助は、水冷を目的とした...
詳細を見る -
蒸留前の越冬と脱ガスの利点
953オイルを蒸留する前に、冬化とガス抜きの手順を踏む必要がある。油脂、ワックス、その他の不活性で不要な化合物を除去する。脱ガスは、沸点の低い溶剤やその他の不活性物質を除去する。
詳細を見る -
単一流体加熱冷凍システムの温度サイクル故障解析
1081各メーカーの一流体冷暖房システムの性能は異なります。LNEYAでは、冷暖房温度の問題を解決するために、高構成の単一流体冷暖房システムの開発に取り組んでいます。
詳細を見る