駅全体を検索


ニュースセンター

Chiller cooling glass reaction tank

Accurate temperature control:

  • •Chillers are generally able to provide high-precision temperature control, usually with a control accuracy of ±1°C or less, and some high-end models can reach ±0.1°C.
  • Ensure the temperature of cooling water is stable through PID controller or other advanced temperature control technology.

広い温度範囲:

  • Chillers can provide cooling capacity from room temperature to low temperature (such as 0°C to -40°C) according to different needs.
  • This wide temperature range makes chillers suitable for a variety of chemical reactions.

Fast cooling capacity:

  • Chillers can quickly cool cooling water to the required temperature and are suitable for applications that require fast cooling.
  • Fast cooling helps improve experimental efficiency, especially in experiments that require frequent changes in temperature conditions.

Circulating cooling system:

  • Chillers are usually equipped with a circulating cooling system, which circulates cooling water between the reaction tank and the chiller to remove heat from the reaction tank.
  • The circulation system can ensure uniform cooling and avoid local overcooling or overheating.

Automatic control:

  • Chillers usually have automatic control functions, which can automatically adjust the operation of the cooling system according to the temperature in the reaction tank.
  • Automatic control helps save labor costs and improve operational efficiency.

Safety measures:

  • Chillers usually have a variety of safety measures, such as over-temperature protection, over-pressure protection, and leak detection.
  • Safety measures help ensure the safe operation of the equipment and prevent accidents.

Recommended Products

  • LT -45℃~30"      /&gt;<figcaption><span>速い液体冷却のための低温冷却の循環器 1.資源を節約する循環の冷凍のために水と混合されるエチレン・グリコールを使用できます 2.Circulating パイプラインの設計は、t.を延長します。</span></figcaption></figure></a></div><div class=LT -45℃~30

    速い液体冷却のための低温冷却の循環器 1.資源を節約する循環の冷凍のために水と混合されるエチレン・グリコールを使用できます 2.Circulating パイプラインの設計は、t.を延長します。

    もっと見る
  • LT 10℃~30"      /&gt;<figcaption><span>水資源の節約及び循環の冷却 1.資源を節約する循環の冷凍のために水と混合されるエチレン・グリコールを使用できます 2.Circulating パイプラインの設計は、循環の冷却の使用時間を延長します。</span></figcaption></figure></a></div><div class=LT 10℃~30

    水資源の節約及び循環の冷却 1.資源を節約する循環の冷凍のために水と混合されるエチレン・グリコールを使用できます 2.Circulating パイプラインの設計は、循環の冷却の使用時間を延長します。

    もっと見る
  • LT -25℃~30"      /&gt;<figcaption><span>輸入されたブランドの半閉鎖したピストン圧縮機、半閉鎖したピストン二段圧縮機、半閉鎖したねじ圧縮機を使用して急速な冷凍 1.エチレングリコールの混合物を使用することができる。</span></figcaption></figure></a></div><div class=LT -25℃~30

    輸入されたブランドの半閉鎖したピストン圧縮機、半閉鎖したピストン二段圧縮機、半閉鎖したねじ圧縮機を使用して急速な冷凍 1.エチレングリコールの混合物を使用することができる。

    もっと見る

ロード...

已经是到最后一篇内容了!」。