超低温循環式冷凍機のフロスティングの理由
Frosting will appear when many users take advantage of ultra low temperature recirculating chillers, while some are not. It is confusing and whether it is relevant to refrigeration.
First of all, why does ultra low temperature recirculating chillers frost? To sort it out, we can turn our eyes on the reasons of direct-cooling ultra low temperature recirculating chillers. The frost is a white crystal of vapour which will congeal on the surface of ultra low temperature objects.
The air will frost on the surface of the inner wall inside ultra low temperature recirculating chillers, which is the root cause. It will affect the heat transfer efficiency, resulting in the decline of refrigerating capacity, so the users should remove it manually.
We understand why the ultra low temperature recirculating chillers will frost on one hand, and for the other hand the air-cooled one is frostless. Are their reasons against each other? The principle of that is the air-cooled ultra low temperature recirculating chillers applies air to refrigerate. When high temperature air flows through the inner evaporator, both of them will change the heat directly because they are in opposite conditions so that the temperature of air will lower.
Meanwhile, cool air is blown in the ultra low temperature recirculating chillers, which is exactly what air-cooled one uses for cycling constantly to reduce its own temperature. However, vapor always exists in the air, so it becomes solid when it freezes, which shows that whenever heat transfer happens, frosting will be in the ultra low temperature recirculating chillers.
In fact, air-cooled ultra low temperature recirculating chillers is carried with frost, but only on the surface of the evaporator. When opening the door, we can not see it because the frost is inside. Thus, we call it as frostless on the whole.
Therefore, we make it clear why ultra low temperature recirculating chillers is out of frosting.
関連推奨品
-
Is it right to extend battery life by lowering the ambient temperature?
971The battery can work in a wide temperature range, but this does not allow the battery to be charged under high temperature conditions. The charging process is more delicate than the discharging process, and extreme care must be taken. Extreme cold...
詳細を見る -
研究室用温度冷凍暖房サイクルシステム操作説明書
1012製薬・化学業界の幅広い応用に伴い、実験室温度冷凍加熱サイクルシステムは、製薬・化学業界において、一般的な温度制御機器を支えるものとして一定の地位を占めている。
詳細を見る -
高低温湿熱試験装置のコンプレッサーの説明
1256高温・低温の湿熱試験装置用コンプレッサーの種類の違いは、しばしば価格に影響する。選ぶ際には、できるだけ低エネルギーの冷凍コンプレッサーを選ぶべきである。今、中国はますます注目している。
詳細を見る -
How to Debug the Expansion Valve of Low Temperature Freezer?
1113The effective operation of low temperature freezer is relevant to the needed refrigerating effect. It is crucial to correct expansion valve if better cooling effect is wanted. So, how to debug the expansion valve of low temperature freezer?During ...
詳細を見る