How to choose a power battery test evaporator?
The corrosion of ferrous metals by salt water is very strong, and its corrosion is more severe when it comes into contact with air. Therefore, as far as the production process permits, closed loops should be used as much as possible. For volatile refrigerant circulation systems, a closed cycle must be used. In both cases, the horizontal battery tube evaporator is a suitable choice for the power battery test group. The tank immersed evaporator is used in an open circulation system with a non-volatile coolant. This type of evaporator is preferred for production processes that use iced ice cubes to make ice. Water tank immersed evaporators can also be used for power battery test refrigeration systems that cool or freeze bagged food in brine and concentrated spray air conditioning.
When the power battery test uses a tank immersed or shell-and-tube evaporator, the working temperature of the brine should be about 5 °C higher than the refrigerant evaporator temperature, and the freezing point of the brine should be 5-8 lower than the refrigerant evaporation temperature. °C (take 5 to 6 °C for the tank immersed evaporator and 6 to 8 °C for the shell and tube evaporator). For the power battery test, the cooling fan is usually used to increase the cooling temperature. For the freezing of the small cold storage, the shelf type pipe or the wall pipe and the top pipe can be used. For the low-evaporation power battery test evaporator, Note the effect of the height of the refrigerant liquid column on the evaporative temperature of the power battery test. The lower the evaporation temperature, the greater the influence of the liquid column. Therefore, certain measures should be taken to reduce the height of the liquid column in the evaporator.
The operation of the evaporator for the power battery test is relatively convenient, so it is better to choose the evaporator of the brand as much as possible.

関連推奨品
-
循環式冷凍機の機器故障アラームの対処法
1272循環式冷凍機の使用中に故障やアラームが発生した場合、どうすればいいのでしょうか?生産性を確保するためには、このような問題を迅速に解決する必要があります。私たちはまず、故障やアラームの原因を理解し、さまざまな対処法を採用する必要があります。
詳細を見る -
Why choose LNEYA’s reactor automatic temperature control equipment?
1306With the rapid development of pharmaceutical and chemical industry, the market demand for automatic temperature control equipment for reactors is expanding. The requirements for automatic temperature control equipment for reactors are also rising,...
詳細を見る -
化学工業における工業用冷水機のデバッグ手順
1071化学企業で工業用ウォーターチラーの設置が完了した後、運転の初期段階で一定のデバッグを実施する必要がある。入念なデバッグを行うことで、初めて工業用ウォーターチラーに隠れたトラブルがないかどうかを突き止めることができるのだ。
詳細を見る -
Summary – the cause of the failure of the 85 ° C ultra-low temperature refrigerator
935-85 ° C ultra-low temperature refrigerator in industrial cold treatment, with the development of industry, the scope of use is also wider. However, in the process of use, it will inevitably lead to failure, so how much do you know about common fau...
詳細を見る