Rapid temperature change test chamber temperature control instructions
The selection of the humidity range of the rapid temperature change test chamber should be noted that the corresponding temperature range should be indicated after the humidity index or the dew point temperature should be given. Because relative humidity is directly related to temperature, for the same moisture content, the higher the temperature, the lower the relative humidity. To achieve high temperature and high humidity, it is only necessary to spray water vapor or atomized water droplets into the air of the cabinet to humidify. Low temperature and low humidity are relatively difficult to control, because the moisture content at this time is very low, and sometimes it is much lower than the moisture content in the atmosphere, and it is necessary to dehumidify the air flowing in the tank to make the air dry.
The common rapid temperature change test chamber generally refers to a constant rapid temperature change test chamber, which is controlled by setting a target temperature and the test chamber has the ability to automatically thermostat to the target temperature point. The control method of the constant temperature and humidity test chamber is similar. Set a target temperature and humidity point. The test chamber has the ability to automatically adjust the temperature to the target temperature and humidity point. The high and low temperature alternating test chamber has the program of setting one or more high and low temperature changes and circulations. The test chamber has the ability to complete the test process according to the preset curve, and can control the temperature rise within the range of heating and cooling rate capability. The rate of temperature drop, that is, the temperature rise and temperature drop rate can be controlled according to the slope of the set curve.

Similarly, the high and low temperature alternating heat and humidity test chamber also has a preset temperature and humidity curve, and the ability to control according to presets. Of course, the alternating test chambers all have the function of a constant test chamber, but the manufacturing cost of the alternating test chamber is higher, because the alternating test chamber needs to be equipped with a curve automatic recording device, a program control device, and the test chamber must be solved in the working chamber. When the temperature is high, the refrigerator is turned on. Therefore, the price of the alternating test chamber is generally 20% higher than the price of the constant test chamber. Therefore, we should be realistic and take the test method as the starting point, choose a constant test box or an alternating test chamber.
Different rapid temperature change test chamber manufacturers have different quality, so users need to understand the rapid temperature change test chamber and make more detailed choices.
関連推奨品
-
Shutdown method in the case of high-precision high-low temperature circulator failure
1093The high-precision high-low temperature circulator is one of the equipments used in the pharmaceutical and chemical industry to support various reactors. If users encounter an abnormal power outage during use, they should pay attention to operatio...
詳細を見る -
なぜ鍛造機には冷却加熱温度制御装置が必要なのか?
785ワークピースと金型の温度制御は、鍛造・スタンピングマシンの作業工程、特に熱間加工作業において極めて重要です。冷却、加熱、温度制御システムの鍛造・プレス機械への応用は...
詳細を見る -
空冷式チラーの特徴と利点
11291.空気冷却されたスリラーの構成空気によって冷却されるスリラーは圧縮機のタイプに従って空気冷却された渦スリラーおよび空気冷却されたねじスリラーに分けることができる。空冷式ボルテックスチラーは、主にボルテックスコンプレッサー、エバポコンプレッサー、スクリューコンプレッサーから構成されています。
詳細を見る -
LNEYAスクリューチラーの蒸発器の特徴
1629スクリュー冷凍機の冷却能力は、ユニット全体のエネルギー消費量と運転経済性に直結しており、注目に値する。特に、コールドステーションを設計する場合、単一の冷凍機は...
詳細を見る