低温実験用特殊装置におけるエバポレーターの冷凍システムへの影響
低温実験専用機器は、LNEYAの実験室用冷凍加熱装置です。エバポレーターの重要性は自明である。では、蒸発器は冷凍システムにどのような影響を与えるのだろうか。その原理は、以下の通りである。
According to different models, the choice of evaporators for low-temperature experiment special instruments is also different, such as box-type low temperature experiment special instruments, using water tank coil evaporator; open low temperature experiment special instrument and screw type refrigerator, then choose Shell and tube evaporator; for special instruments for acid and alkali resistance low temperature experiments, titanium tube evaporator or stainless steel plate exchanger can be selected. An ice water machine can have a variety of options, of course, can be customized according to user needs.
The temperature condition of the evaporator of the low-temperature experiment special instrument: under normal circumstances, the outer surface of the evaporator is very cold, and the condensation water droplets are continuously dripped, and the temperature of the inlet and outlet air is relatively large, usually Δt can be 12~14 ° C. The surface of the evaporator is not too cool, there is not much dew, or condensation, and the sound of the refrigerant flow is very loud, and the temperature difference between the inlet and outlet is small. The reason is that the refrigerant amount is insufficient, or the expansion valve opening degree is small.

The factors affecting the evaporation temperature of special instruments for low temperature experiments are as follows:
Evaporator pipe oiling: Under normal circumstances, due to the mutual solubility of lubricating oil and refrigerant, oil film will not form on the surface of the heat exchanger, and the thermal resistance of the oil film may be disregarded. However, in the case of additional lubricating oil, it must be the same as the original one. Lubricating oil to prevent the formation of oil film. Air filter plugging: The filter must be replaced regularly to ensure the required air circulation for the air conditioner. Dry filter plugging: In order to ensure the normal circulation of the cooling enthalpy, the refrigeration system must be kept clean and dry. If the system has impurities, the drying filter will be blocked, the system will be difficult to supply liquid, and the cooling effect will be affected. Too little refrigerant, additional refrigerant.
The evaporator of the low-temperature experiment special instrument also has certain requirements in terms of quality. The brand has a certain quality guarantee, so that the operation will be more stable.
関連推奨品
-
Operation and Maintenance of Small Water Chiller Units
9402. Air-cooled module internal filter, in order to better filter impurities in the water system, the protective plate heat exchanger is generally more than 40 meshes, that is to say, its filter is more dense and finer than other brands. The advanta...
詳細を見る -
Brief introduction of explosion-proof curve heating and cooling thermostat
982The explosion-proof curve heating and cooling thermostat SUNDI series adopts compressor refrigeration and linkage heating technology, an integrated piping system, and a plate heat exchanger. It is suitable for equipment connecting reactors for ref...
詳細を見る -
-
マイクロチャンネル反応器サーモスタット制御空冷式冷凍機コンプレッサーのトラブルシューティングメソッド
1224空冷チラーは、マイクロチャンネルリアクター業界で広く使用されている温度制御装置です。無錫広雅LNEYA有限公司は、マイクロチャンネル反応器産業用の冷熱源サーモスタット制御空冷チラーを生産しています。
詳細を見る