高温・低温循環タンク冷凍プロセスの説明
高温・低温循環タンクを使用する過程で、不適切な使用による些細な問題が発生する可能性があり、無錫官也高温・低温循環タンクの冷凍工程に問題が発生する可能性があり、その後、...
Most high and low temperature circulating tanks cool the media for cooling, but some simple techniques that rely on air or water contain a cooling coil that regulates temperature. The high and low temperature circulation tanks are used as a closed loop system for complete packaging, including hot and cold water units, condensers and circulation pumps, high and low temperature circulation tank expansion valves, partial cold water tanks, and temperature control stations. The closed loop industrial screw high and low temperature circulation tank recirculates water cooling equipment and instrument cleaners at constant temperature and pressure, increasing stability and repeatability.

If there is a high temperature difference between the two, the large external tank will be used to store cold water. In this case, the cooling water does not go straight from the cooler application, but goes deep into the outside of the tank as a “temperature buffer sorting behavior. The cold water tank is much larger than the internal water tank. Cold water from the external fuel tank application And returning hot water from the application can be traced back to the external fuel tank, not to the unit.
One of the new developments in high and low temperature circulating tanks is air cooling, not the use of cooling water. In this case, the condenser is not cooled with hot air refrigerant, but is used by a cooling water cooling tower. This development allows for more than 15% and allows for a reduction in energy demand in the cooler due to the small area of surface water, condensers and fans. In addition, the fans allowed a significant reduction in noise levels.
At the same time, the high and low temperature circulation tanks also need to pay attention to the usual maintenance work, so that the high and low temperature circulation tank can exert a large operating power.
関連推奨品
-
ルネヤの極低温産業用冷凍機を導入されるお客様へ注意事項
1220ひとつ。低温工業用冷凍機を設置する際には、いくつかの設置条件に注意する必要がある。1.低温の産業スリラーは横の位置に直接取付けられるべきですそれを逆さまに取付けなかったりまたは dia...
詳細を見る -
反応冷却に極低温冷凍機を使用するポイント
1108極低温冷凍機はチラー、極低温冷凍サーキュレーターとも呼ばれる。低温-110度の冷凍を実現する実験装置である。この種の装置は単流体冷凍機でよく使用される。
詳細を見る -
Why choose LNEYA’s reactor automatic temperature control equipment?
1305With the rapid development of pharmaceutical and chemical industry, the market demand for automatic temperature control equipment for reactors is expanding. The requirements for automatic temperature control equipment for reactors are also rising,...
詳細を見る -
小型ウォーターチラーユニットの運転とメンテナンス
9432.空冷モジュール内部フィルターは、水システム内の不純物をよりよくろ過するために、保護プレート熱交換器は、一般的に40メッシュ以上である、つまり、そのフィルタは、他のブランドよりも緻密で細かいです。アドバンタ...