Refrigeration principle of LNEYA glycol chiller system
Glycol Chiller System SUNDI -10℃ ~ 200℃, as we can tell from its name, it is to use Glycol as the refrigeration agent for the chiller.
In the all air environment, because of the low temperature in the outdoors, it is impossible to use a cooling tower to supply the inner area directly with the cold air-conditioner. In addition, the cold air in the outdoors could be used directly as refrigerator source,with glycol as refrigerant, it can introduce the natural cold air into the inner area and supply cold air-conditioner. If we need to heat the outer area and provide cooling for the inner area, we can turn off the chiller and still use the boiler or the urban hot water as the heat source to heat the outer area.
Install plate heat exchanger in the outdoor, and the outdoor cold air is introduced into the plate heat exchanger by the fan. The glycol solution and the outdoor cold air are exchanged in the plate heat exchanger. The cooled glycol solution enters into the air conditioners in the inner area and exchange with mixed air. Then the mixed air enters into the inner room with lower temperature and supply cooling. The temperature of glycol solution rise up, it comes back to the plant heat exchanger in the outdoor again, exchange heat with the cold air in the outdoor and continue this cycling after the temperature is lowered. This way of heat exchange is usually used in the heat recycling system.
It is a very energy-saving way that use glycol as a refrigerant to introduce the cold air in the outdoors to supply cooling for the inner area. All we need to do is to install a plant heat exchanger in the outdoor when it works, the cold water equipment closed, opening the fan and the air conditioners can bring cooling for the inner area. In this way, we can save energy and reduce the cost.

関連推奨品
-
産業用冷凍機の基本構造マニュアル
1224工業用冷凍機は、コンプレッサー、凝縮器、蒸発器、膨張弁、およびその他の付属品で構成されています。1.圧縮機:工業用冷凍機システムにおいて、コンプレッサーは冷凍を確保するための動力である。コンプレッサーを使用することで、冷凍...
詳細を見る -
液体窒素コールドボックスの停電による影響は?
1208Different industries have different temperature requirements for liquid nitrogen cryogenic cryostats. Of course, there are many types of cryogenic cryostats. The refrigeration methods used in different industries are different. Wuxi Guanya LNEYA u...
詳細を見る -
冷却水循環装置が主水循環を必要とする理由
1191The supplement of the water cycle is directed to a water-cooled cooling water circulator, and the air-cooled cooling water circulator does not have this problem. The water-cooled cooling water circulator needs cooling water during normal operation...
詳細を見る -
新エネルギー自動車とLNEYAバッテリー試験温度制御ユニットの密接な接触
1483エネルギー問題の現状と自動車産業の活況を踏まえ、新エネルギー自動車は現代の自動車産業と同様にタイムリーな存在となっている。新エネルギー車のバッテリー部分は、自動車産業の発展において決定的な役割を果たしている。
詳細を見る