-20 ° C冷凍庫メーカーは蒸発器を見て何を選ぶ?
In the process of producing industrial freezer, the selection of a suitable evaporator is also very important for the freezer, because the choice of suitable evaporator is better for better operation of the -20 °C freezer.
The evaporator is generally equipped with a -20 °C freezer, and the user does not have to choose. However, in order to better maintain the refrigeration system and ensure its efficient operation, some factors should be noted. Due to the influence of the height of the refrigerant liquid column of the -20 °C freezer manufacturer, the evaporation temperature at the bottom of the full liquid evaporator is higher than the evaporation temperature of the liquid surface. Different refrigerants have different effects on the evaporating temperature of different liquid levels due to the height of the hydrostatic fluid. Regardless of the refrigerant, the lower the evaporation temperature of the liquid surface, the greater the effect of the hydrostatic height on the evaporation temperature. Therefore, the effect of the hydrostatic height on the evaporation temperature can be ignored only when the evaporation pressure is high. When the evaporation temperature is low, it cannot be ignored. That is to say, it is uneconomical to use a full liquid evaporator at this time.
If the -20 ° C freezer evaporating temperature is lower than the brine solidification temperature, the brine may freeze. In one process of the brine, the temperature of the brine is low and the possibility of freezing is relatively large. When water is used as the brine, it is theoretically possible that the inner wall temperature of the tube can be as low as 0 °C. However, for safety reasons, the inner wall temperature of the tube at the outlet end of a process is usually maintained above 0.5 °C. In the case of brine as a coolant, according to the same principle, the inner wall temperature of the pipe should be higher than the solidification temperature of the brine by more than 1 °C.
When the -20 °C freezer refrigerant flows through the evaporator, the pressure loss is caused, and the pressure p2 of the refrigerant at the outlet of the evaporator is inevitably lower than the pressure p1 at the inlet, thereby lowering the suction pressure of the compressor, resulting in a decrease in the refrigeration capacity. According to different models, the choice of evaporator is different, such as box type freezer, using water tank coil evaporator; open type freezer and screw type freezer, use shell and tube evaporator; Acid-base freezer, you can choose titanium tube evaporator or stainless steel plate exchanger, of course, can be customized according to user needs.
In general, manufacturers have certain principles in selecting evaporators. Basically, brand evaporators are one of the manufacturers’ choices.

関連推奨品
-
低温・高温エージング試験装置の選び方は?
1123The refrigeration capacity and temperature range of materials in different industries are different. Generally speaking, the cooling capacity is divided into 80kw, 120kw, 180kw, 240kw, 360kw, and the cooling temperature ranges from -25°C to -5°C. ...
詳細を見る -
半導体水冷温度制御プラットフォームのスロットルコンポーネント
1190The throttling component of the semiconductor water-cooled temperature control platform is one of the four major components that are indispensable for the refrigeration system. Its function is to reduce the pressure of the high-pressure liquid com...
詳細を見る -
Heat transfer oil of explosion-proof cooling and heating circulator
959Explosion proof cooling and heating circulator is a commonly used temperature control equipment in laboratories. It is used in pharmaceutical, chemical, biological and other industries to provide heat and cold sources for reactors, reactors, etc. ...
詳細を見る -
The Importance of Choosing a Quality Chiller Manufacturer
763The first is professional operators.Professional refrigeration practitioners are the prerequisite for the maintenance, repair and maintenance of the chiller. If there are no professionals to work on the refrigeration equipment, it will not only c...
詳細を見る