低温チラーは金型産業にどのように適用されるか?
As you all know, the 低温チラー is widely used, especially in the mould line. So does everyone know how it works in the mould industry? If you don’t know, let’s have a look with me.
When using the 低温チラー to cool the mould, it usually cools the mould together with the injection machine. Generally speaking, the mould is quite a heat exchanger. Heat is transferred from melting to the mould, and then from the mould to the cooling medium for cooling. As we all know, mould forming is inseparable from cooling function. When choosing the 低温チラー, we should try to choose the 低温チラー with better quality and higher cost. The relative operating power is higher. Compared with the ordinary 低温チラー, it can increase certain output and obtain certain benefits in a longer period of time.
In the practical application of the 低温チラー and models, the temperature difference of ice water at the inlet is determined according to the requirements of products. In many cases, the temperature difference of 3-5 degrees is more ideal. The smaller the temperature difference, the larger the ice flow needed to take away the same heat. On the contrary, the smaller the ice flow needed.
Also, when using the 低温チラー, it is necessary to constantly check the water quality of the 低温チラー. Once the water quality changes over a long period of time, it will produce some corrosion phenomena. If not handled in time, it will produce scale, which can produce certain insulation effect. In serious cases, it will reduce the effect of conversion. Therefore, when configuring the 低温チラー, it will produce some corrosion phenomena. Water quality must be selected well. In addition, scales can be treated regularly in time or equipped with water treatment softening equipment.
In the process of using the 低温チラー for cooling, it is necessary to select the pressure of ice water. Another point is that the pipeline of the 低温チラー must be insulated and heat-insulated, otherwise it will cause the loss of cooling capacity and form condensation water on the outer wall, which will affect the use of the 低温チラー.
関連推奨品
-
ウォーターチラーにおけるコンデンサーのメンテナンス方法
1108空冷式コンデンサーは主に空冷式ウォーター・チラーで使用される。冷却媒体として空気を使用する。空気中にはホコリや雑物が含まれていることが多いため、コンデンサーのフィン外面にホコリや雑物が付着することがあります。過...
詳細を見る -
About 60p Refrigerated chiller energy consumption is too large
1344The performance of 60p Refrigerated chiller of different manufacturers is different, and the energy consumption is also different. If the energy consumption of 60p Refrigerated chiller is too large, it is necessary to check in time to see if ther...
詳細を見る -
なぜエナメル・リアクターの使用は危険なのか?
1235琺瑯反応釜の琺瑯層は、寒くても熱くても破裂しやすい。なぜなら、ホーロー反応釜の表面はホーロー層が焼結しており、200℃を超えるとホーロー層が溶けてしまうからです。
詳細を見る -
冷暖房用サーキュレーターの日常メンテナンス方法
1018After the heating and cooling circulator has been running for a long time, certain maintenance work needs to be carried out, so what should be paid attention to? To ensure the normal operation of the heating and cooling circulator after it is star...
詳細を見る