Temperature cycle failure analysis of single fluid heating refrigeration system
The performance of single-fluid heating and cooling systems of different manufacturers is different. LNEYA is committed to creating a high-configuration single-fluid heating and cooling system to solve the problem of cooling and heating temperature control for users. How to solve the problem of temperature cycle failure in single-fluid heating and cooling system? ?
The basic parameters of the temperature cycling of the single-fluid heating and cooling system are mainly six: 1 upper limit temperature; 2 lower limit temperature; 3 temperature change rate; 4 upper limit temperature holding time; 5 lower limit temperature holding time; In the single-fluid heating refrigeration system temperature cycle test, the uniformity of the gas flow in a single-fluid heating refrigeration system is an important parameter that will affect the temperature change rate of the product. The mechanism and sensitive components of temperature cycle induced failure: temperature cycling makes different materials with different expansion coefficients expand differently, causing peeling, cracking, and sensitive components such as paint coating.
The temperature cycling of the single-fluid heating and cooling system makes the joints that are screwed or riveted loose, and the sensitive components such as screws and riveted parts; the temperature cycle makes the press-fit joints with insufficient mechanical tension slack; the high-low temperature alternating test chamber temperature cycles make the material Poor solder contact resistance increases or induces an open circuit, and its sensitive components such as resistive components; temperature cycling causes contact corrosion and contamination, and its sensitive components such as alloy materials.
Therefore, for the user, the high-performance configuration of the single-fluid heating and cooling system is very important, the cheap single-fluid heating and cooling system is not necessarily easy to use, and the expensive single-fluid heating and cooling system will not go wrong. (This article is from the source network, if there is any infringement, please contact LNEYA to delete, thank you.)
関連推奨品
-
Why is there air in the reactor temperature control system?
952The impurity gas in the reactor temperature control system is to increase the condensing pressure of the refrigeration system, thereby increasing the condensing temperature, increasing the exhaust temperature of the compressor, increasing the powe...
詳細を見る -
LNEYA試験室用循環式冷凍機はどのような機器に使用できますか?
876実験室用循環式冷凍機は、科学研究や工業生産において幅広い用途があり、様々な実験や機器に正確な温度制御を提供します。以下は、一般的なシナリオです。
詳細を見る -
Method for connecting reaction kettle and electric control cabinet of reaction equipment
1004The supporting equipment of the reaction kettle is the temperature control product provided by our company for the majority of users for the users. When the user selects the equipment for the reaction kettle, it is necessary to understand the conn...
詳細を見る -
Hot and cold rapid temperature change test chamber common fault
1054In the high-temperature test of the hot and cold rapid temperature change test chamber, once the temperature change does not reach the test temperature value, in this case, the electrical system can be inspected and the faults can be eliminated on...
詳細を見る