ルネヤの高温・低温冷却サーキュレーターの説明書
高温・低温冷却サーキュレーターは、LNEYA社の冷凍・暖房温度制御技術を応用して開発・製造されたものです。高温・低温冷却サーキュレーターを使用する際は、...
The high and low temperature cooling circulator is a device that uses mechanical refrigeration to obtain low temperature heating tube heating to obtain high temperature, a leak-free shielding pump as a circulation pump, a double-layer glass reaction bath, a stainless steel sandwich reaction kettle and the like. Before using the high and low temperature cooling circulator, open the wooden box and first install the inlet and outlet valves on the liquid inlet. (Note: The upper and lower sides of the machine are marked with inlet and outlet ports, the valve is a shut-off valve, the valve medium flows in a direction, and the valve is marked with a flow direction. The valve and the reaction kettle are docked with a hose, and the inlet and outlet of the reaction kettle should be driven in, out, and react. Keep the liquid in the kettle. Open the high and low temperature tank and add the liquid to the machine to open the machine’s circulation switch, let the liquid circulate throughout the system. (Note: To evacuate the air in the system) The cooling medium should meet the conditions of use. That is, it does not freeze under low temperature conditions, and does not boil under high temperature conditions)
If the high and low temperature cooling circulator requires a temperature of 150 ° C, set the temperature control table to 150 ° C to turn on the heating switch and the cycle switch, and the machine will start working. When the material needs to be cooled to room temperature at high temperature, it is necessary to turn off the heating and turn on the pre-cooling. At this time, the material can be cooled to room temperature by cooling. When the material needs to be lower than room temperature, first reduce the material to room temperature, then set it to the required equipment, turn on the refrigeration, the compressor will enter the working state, and the machine will start to cool down.
During the use and maintenance process, try to operate according to the requirements. It is not recommended to change the program by yourself to avoid the failure of the high and low temperature cooling circulator. (This article is from the source network, if there is any infringement, please contact Lneya to delete, thank you.)
関連推奨品
-
-
-
なぜ半導体パッケージングや検査選別機には冷凍機が必要なのか?
1199半導体パッケージの検査工程、特に選別機(テストプローブステーション)の温度制御工程では、主に以下の理由から冷凍機が使用されている:温度安定性と精度
詳細を見る -
Application of Microchannel Reactor Temperature Control System in the Laboratory
894Application of Microchannel Reactor Temperature Control System
詳細を見る