The Effect of Heating Cooling Translator
The whole liquid circulation of the heating and cooling circulator is closed with the expansion vessel. The expansion vessel and the liquid circulation are adiabatic and do not participate in the liquid circulation. This is just a mechanical connection. Whether the temperature of the liquid circulation is high or low, the medium in the expansion vessel is always below 60 degrees.
Heating cooling circulator all closed system, extend the life of the thermal fluid, temperature range is extremely wide, with no need to replace liquid medium, the refrigeration system uses air-cooled compressor refrigeration, high cooling speed, low noise, high and low temperature all-in-one airtight microcomputer with internal overtemperature alarm function, upper and lower limits can be arbitrary set within ten degrees, sometimes there are some deviations in the measurement, airtight high and low temperature all-in-one can officially adjust the deviation in the measurement.
What is the function of the heating and cooling circulator? In the commissioning and operation stage of the heating and cooling circulator system, if it is found that the cooling capacity of the cooling and heating circulator system is obviously insufficient and no other abnormalities are found after inspection, attention should be paid to the refrigerant; If the heating cooling circulator system dryer filter or expansion valve block, and the blockage is the browns color wax-like or black sludge form foreign bodies need to focus on refrigerant when hot and cold cycle machine appeared in the process of system running high, low pressure or temperature anomaly, or stop state system balance when abnormal pressure (can control temperature of the refrigerant pressure characteristic table), need to focus on the refrigerant. If these anomalies occur in the heating and cooling circulator, it is recommended that the refrigerant can be extracted from the system for purity testing to screen out the risk of poor refrigerant quality.
関連推奨品
-
What should I pay attention to when replacing a water-cooled chiller compressor
1015Once the compressor of the water-cooledchiller fails, the compressor needs to be replaced in time, but the replacementof the compressor is not as simple as imagined.Before the water-cooled chiller compressoris replaced, the reasons for the dama...
詳細を見る -
Semiconductor Test Temperature Cycle Chiller Development
1133The semiconductor chip IC industry is currently a relatively new industry in China. As the requirements of the chip industry become higher and higher, the test difficulty is also constantly strengthened. To this end, LNEYA introduced the semicondu...
詳細を見る -
グリコールチラーの温度説明
1025For users and friends, it is necessary tohave a deep understanding of glycol chillers before use. It is recommended toknow the temperature in various equipment such as refrigeration system,evaporating temperature, condensing temperature, etc.If...
詳細を見る -
Industry and introduction of low temperature chiller
962In petroleum refining, petrochemical industry, organic synthesis, chemical products and other industrial production, refrigeration technology must be applied to control the reaction temperature during processes such as liquefaction, condensation, ...
詳細を見る