超低温フリーザー電源および電子制御機器システムの説明
Ultra-low temperature freezer needs to be tested after a long time of use. What should be paid attention to when the power supply and electronic control instrument system are inspected?
Check the ultra-low temperature freezer power supply and the electronic control instrument system. Before starting the power, check whether the power distribution capacity matches the unit power, and whether the selected cable diameter can withstand the host operating current. Check whether the electrical system is consistent with the unit. The unit is electrically: three-phase five-wire system (three phase lines, one neutral line, one ground line, 380V ± 10%). Check if the power supply line of the compressor is connected tightly. If it is loose, retighten it. The torque at the compressor wiring is 500kg/cm. Due to factors such as long-distance transportation and lifting, the screws may be loose. Failure to do so may result in damage to electrical components (such as air switches, AC contactors, etc.) and compressors in the main control cabinet.
Use a multimeter to carefully check all the electrical circuits of the ultra-low temperature freezer, check that the wiring is properly installed in place; use megaohm measurement to make sure there is no short circuit in the case; check that the ground wire is properly installed in place, and the insulation resistance to ground is greater than 2MΩ; check if the power cable is suitable. Capacity requirements. Check if the disconnect switch is installed on the power supply line of the supply unit. All the wiring of the main circuit in the control cabinet and the external wiring of the control circuit can be energized after comprehensive inspection (such as crankcase oil heater, compressor electronic protector, circulating water temperature sensor, target flow switch wiring, pump connection) Control, etc.); Check if the terminal bolts are tightened and there is no looseness.
The performance of the power supply and the electronic control instrument are more important in the operation of the ultra-low temperature cold box, so regular inspection is recommended.
関連推奨品
-
Effect of cooling and heating temperature cycle during emulsification
1576Emulsification is the effect of a liquid in which even tiny droplets are evenly dispersed in another liquid that is incompatible with each other. Emulsification is a liquid-liquid interface phenomenon. Two immiscible liquids, such as oil and water...
詳細を見る -
低温冷凍機シリーズのご紹介-低温プロセス冷凍機
927熱音響冷凍技術は、幅広い応用が期待できる新しい冷凍方法である。過去30年間における冷凍・低温技術の大きな進歩のひとつである。熱音響エンジンは、熱音響効果を利用して...
詳細を見る -
中秋節感謝晩餐会、無事終了
1401The autumn wind is refreshing, and the Mid-Autumn Moon is rounder. At the juncture of time, the annual Mid-Autumn Festival is about to usher in. In this beautiful festival, Wuxi Guanya is full of love and the Mid-Autumn Festival Appreciation Dinn...
詳細を見る -
超低温循環式冷凍機をより省エネにする方法
1073現代では、環境保護と省エネが開発テーマであり、工業用冷凍機も同様である。では、工業用チラーをより省エネにするにはどうすればいいのでしょうか?まず、工業用冷凍機の配管スケールを防止・低減する。
詳細を見る