低温チャンバーの3つの試験方法の比較
The method of guaranteeing the fluctuation of uniformity in high and low temperature test box is to adopt the wind circulation mode, in which the motor drives the fan to produce the wind circulation, thus forming the direction of wind speed. Non-forced air circulation test is a kind of test to simulate the influence of free air conditions, which is more suitable for the test of heat dissipation test samples. When forced air circulation is not used or test conditions are not guaranteed, forced air circulation can be used. One of the methods used in the test chamber is large enough to meet the test requirements without forced air circulation, but the required low temperature can not be maintained without forced air circulation in the chamber. Forced air circulation is required for refrigeration or heating of 低温室.
2. Non-heat dissipation test samples and heat dissipation test samples
When the temperature of the test sample is stable during the conditional test period, the hottest spot temperature on the surface of the test sample is higher than the ambient atmospheric temperature by 5 degrees under the condition of free air, which is considered to be heat dissipation, whereas the non-heat dissipation test sample is considered to be heat dissipation. All the storage test and the test period without power or load, the test samples are non-heat dissipation test samples, the test using low temperature test method.
3. Non-heat dissipation test samples
Temperature gradient test of low temperature chamber(the former is a rapid temperature change test box and the latter is a cryogenic tester).
(1) Temperature gradient test: first, test samples with room temperature are put into the same room temperature test box. Then turn on the cold source to gradually cool the temperature in the box to the specified test temperature. If the test sample is too large or too heavy, or because of the complex functional test wiring, it can not be put into the cryogenic chamber without frosting in the catastrophe test, the test should also be used.
(2) Temperature catastrophe test: first adjust the temperature of the test chamber to the specified test temperature, and then put the test sample with room temperature. This test method is applicable when the known temperature abrupt change does not produce operation on the test sample.
関連推奨品
-
ヒーターに背水を追加したら、冬でもいつでもどこでもお湯が出るようになった
967原理も簡単だ。温水パイプの出口に水パイプを追加し、閉回路を形成する。循環ポンプは給湯器に接続されている。蛇口をひねると、循環ポンプが自動的にお湯を循環させる。
詳細を見る -
強力との協力!LNEYA&シーメンス戦略的協力調印式が成功裏に終了
2623On May 25, 2021, the signing ceremony of strategic cooperation between LNEYA Constant Temperature Refrigeration Technology Co., Ltd. and Siemens (China) Co., Ltd. was held in Wuxi, China. At the signing ceremony, leaders such as Que Yaoyao, direc...
詳細を見る -
What are the installation requirements for lithography chillers?
1100In order to ensure the reliable and normal operation of the chiller of the lithography machine and prevent the failure of the chiller caused by improper water distribution pipeline construction, the following matters should be paid attention to wh...
詳細を見る -
Solution to oil spill of reactor cooling and heating circulator
957When we use some reactor cooling and heating circulators, we will find that the system pressure fluctuates up and down as the temperature rises, and the oil tank is overflowing. So what are the reasons for these conditions in the cooling and heat...
詳細を見る