Low temperature chilled lubricant selection considerations
When you use a cryogenic chilled, you definitely want to know about all aspects of the cryocooler. But one of the things that needs everyone’s attention is that the type of lubricant for the chilled is chosen because there are many influencing factors. When you choose, you need to choose carefully.
There are many types of compressors for cryogenic chilled. Generally, pistons, screws, and centrifugals are commonly used. Among them, the piston type and screw type compressor are in direct contact with the lubricating oil and the refrigerant, so when selecting the lubricating oil, attention should be paid to the mutual influence of the refrigerant. Secondly, the centrifugal type is only used to lubricate the rotor bearing. It is recommended to choose according to the load and the speed when selecting.
In addition to the compressor, it is also possible to select the lubricating oil according to the type of refrigerant, because the refrigerant and the lubricating oil are mutually influential, it should be noted that the selected refrigerant and lubricating oil cannot dissolve each other, and the low-temperature chilled is recommended. The viscosity of the lubricating oil should be as high as one level higher than the refrigerant. It is necessary to ensure that the lubricating oil can be lubricated after dilution, so that the operation of the low temperature freezer will not be affected.

Another option for cryogenic chilled is the evaporation temperature of the refrigerant. Generally, the corresponding freezing point lubricating oil is selected according to the evaporation high temperature and low temperature of the chilled. When freon is used as the refrigerant, the condensation point of the lubricating oil is required. Above the evaporation temperature, if it is ammonia refrigeration, the freezing point will be lower than the evaporation temperature.
Of course, if the working conditions of the cryogenic chilled are different, the lubricating oil is also a little different. If the large, medium, and heavy load is large, try to choose a lubricant with a relatively large viscosity. For a small one, you can choose a lower viscosity.
The choice of lubricating oil for cryogenic chilled is closely related to the operation of cryogenic chilled.
関連推奨品
-
深層循環式冷凍機の高圧故障に対する解決策
988ディープサーキュレーション・チラーは、化学・医薬中間体、石油化学、機械、医療、エレクトロニクス、新素材、航空宇宙、オプトエレクトロニクス技術、新エネルギーなどの製造・加工に使用されるプロセス用冷熱源です。
詳細を見る -
極低温冷凍システムの紹介と利点
1187The medium-sized single-fluid cryogenic refrigerator produced by our company has a cooling temperature range from -150℃ to -5℃, fast cooling speed, safe and reliable, used for rapid liquid cooling, applied to high-tech such as biochemical, freeze-...
詳細を見る -
化学冷凍温度制御ユニットの役割
1099製薬工場や化学工場では、工業生産に関わる反応器内の原料を急速に冷却・冷却する必要があります。この目標を達成するために、反応器は直接冷却・冷却され、それによって...
詳細を見る -
原子炉温度制御システムの選定にはどのような参考資料が必要ですか?
1084原子炉温度制御システムの加熱出力選択は、おおよそ原子炉の大きさに基づいている。原子炉温度制御システムは、原子炉の加熱と冷却に使用される恒温装置である。選択する際、2つの ...
詳細を見る