工業用冷水機の設置およびメンテナンス
As a industrial temperature control device,
industrial water chiller is often in 24-hour operation. Therefore, it is very
important to choose a industrial chiller with good performance. Wuxi Guanya
Refrigeration Technology Co., Ltd. specializes in the manufacturing, research,
development, production and sales of industrial temperature control equipment
such as industrial water chiller and ultra-low temperature chiller. 15 years of
concentration and experience have made LNEYA’s industrial water chiller a
leader in the industry. LNEYA specializes in providing customers with cooling
and heating temperature control solutions, and meets customers’ temperature
needs with superior performance industrial water chiller. In order to maximize
the service life of the industrial water chiller, we need to know the following
installation and maintenance methods in daily use.
Installation precautions: the installation
site of the industrial water chiller must be the floor or installation mat, and
can bear the operating weight of the chiller. It should be placed in a machine
room with a room temperature of 4.4~43.3℃, and sufficient space shall be
reserved around and above the industrial water chiller for daily maintenance.
When the water source and the surrounding environment of the cooling water
tower are bad, the cooling water circuit must be equipped with a Y-type filter
and cleaned regularly. Choose the matching cooling tower according to the
refrigeration capacity of the industrial water chiller. After the chilled water
piping system passes the leak test, it is necessary to wrap the insulation
layer to avoid cooling loss and dripping of the pipeline.
Maintenance method: If the industrial water
chiller has been used for more than 6 months, and refrigeration capacity is
reduced, please arrange staff to clean the radiator. If the industrial water
chiller is equipped with a pressure gauge, check whether the pressure of the
high pressure gauge is higher than 300PSI. If it exceeds, please clean the
radiator or check whether the water hose has been fully opened. The repair is
carried out according to the above operation for several times, but the alarm
signal of industrial water chiller failure is still ringing, please arrange
staff to repair it. After the chiller is out of service for a period of time,
the water pump blade may be solidified due to the water dirt. When starting up
again, the water pump rotor must be loosened first to avoid that the pump blade
does not rotate and burn the motor.
関連推奨品
-
どのような電池パック試験室が実験室に適合しますか?
762実験室でのバッテリーパック試験室の使用は、試験結果の正確性と安全性を保証するために、一連の厳しい要件を満たす必要があります。これらの要件には主に以下の側面が含まれます:温度コン...
詳細を見る -
フラッシュ高温・低温テストチラーのメンテナンスのポイント
974フラッシュ高温・低温テストチラーの購入者は日に日に増えている。購入後、耐用年数が大幅に短縮されたことに気づく人も多い。そのため、運転管理者やメンテナンス担当者は一定の専門的な知識を持っていなければなりません。
詳細を見る -
製薬業界における熱オイル加熱システムの用途
806製薬業界における加熱温度要件は、製薬プロセスや製品調製工程によって異なるため、非常に多岐にわたります。以下は、製薬業界における加熱温度要件の一部です。
詳細を見る -
What are the characteristics and application scope of cryogenic refrigeration circulators?
1157Specializing in the development and production of low-temperature refrigeration circulators, the refrigeration temperature range is from -120 degrees to -30 degrees. Today, let us take a look at the characteristics of low-temperature refrigeration...
詳細を見る