半導体冷却サイクルシステムの冷却不足を解消する方法
について semiconductor cooling cycle system is a device for cooling the semiconductor heat-generating part in the refrigeration equipment. If the cooling capacity of the LNEYA semiconductor cooling circulation system is insufficient during operation, it is necessary to check in time to see what has gone wrong.
半導体冷却サイクルシステムの冷却能力が不足した場合、まずフィルターが閉塞しているかどうかを判断する。フィルターの詰まりには、吸引フィルターの詰まりとドライフィルターの詰まりがある。この時は、洗浄と清掃だけでよい。
By observing to determine whether it is too small or too large for the expansion valve to open, by adjusting the amount of water. The problem of leakage of the filling agent in the temperature sensor of the expansion valve can be solved by opening the cooling tower. A dirty or blocked ice valve can be solved by cleaning. If the bearing of the compressor is worn out, the clearance is too large, and the problem of insufficient cooling capacity can be solved by inspection and replacement. Use components with precise structure, high reliability and long life. To ensure the stable operation of the unit.
The condenser of the semiconductor cooling cycle system selects the shell-and-tube condenser, which can optimize the temperature field distribution and the flow field distribution of the refrigerant, and the heat exchange efficiency is high. The outer fin design of the heat exchange tube enhances the heat exchange condensation and improves the heat exchange efficiency outside the tube. Insufficient refrigerant charge and excessive refrigerant leakage may also cause insufficient cooling capacity in the semiconductor cooling cycle system. These problems can be solved by adding or subtracting the refrigerant charge, leaking, and adding refrigerant after maintenance.
Semiconductor cooling cycle system evaporator with too small evaporator frosting too thick> There are a large number of lubricants in the evaporator or the liquid storage valve of the liquid storage valve is too small, the cooling water is insufficient or the water temperature is too high, etc. The cooling cycle system has insufficient cooling capacity. If the evaporator is too small, it can reduce the heat load or replace the evaporator. If the evaporator frost is too thick, it needs to be frosted regularly. There is a lot of lubricating oil in the evaporator, and the refrigeration oil, condenser or reservoir is recovered. The outlet valve is opened too small, and the outlet valve is properly opened.
In addition, there is excess air in the refrigeration system of the semiconductor cooling cycle system, and the energy adjustment indication is incorrect and needs attention. Excess air in the refrigeration system can be solved by discharging air. If the energy adjustment indication is incorrect, the indicator light may be broken and can be solved by inspection and replacement. The reason for the insufficient cooling capacity is as shown above. It is recommended that users find out that they can contact the manufacturer in time for after-sales solution.
関連推奨品
-
リアクタープロセスサーモスタットの利点
953反応釜のプロセスサーモスタットは、媒体の温度と材料の温度を制御することができます。より正確な反応技術とプロセス制御を必要とするユーザーに適しています。主に...
詳細を見る -
What should I pay attention to when adding refrigerant to a water-cooled chiller
1153私たちの生活の中で、冷凍は誰もがよく知っていると思います。中央空調や工業生産プロセスの冷却業界では、小型の水冷式チラーが一般的です。このユニットは、コンプレッサーで構成されています。
詳細を見る -
電気自動車/ハイブリッド車の冷却試験におけるバッテリー試験温度シミュレーションシステムの効果
1115電気自動車業界では、バッテリーは自動車の重要な一部であり、その性能はハイブリッド車/電気自動車の性能に直接影響する。このため、市場の関連メーカー各社はバッテリー・クー...
詳細を見る -
エチレングリコール冷凍ユニットが猛攻、12年でLNEYAブランド誕生
1326Performance enhanced positioning When performing the cooling and heating reaction, in many cases, the refrigerant cannot cool the object to be cooled by itself. Therefore, we need a coolant (or refrigerant) to cool the refrigeration system in a re...