産業用冷凍機の冷凍特性とは?
If there is a high temperature difference between the inlet and outlet water, then a large external tank will be used to store cold water. In this case, the cooling water will not be directly from the cooler application. Deep into the outside of the tank is a “temperature buffer sort behavior”. Cold water tanks are much larger than internal ones. The cold water goes to the application of external fuel tank and come back as hot water. It can be traced back to external fuel tanks, not to industrial chillers.
産業用チラー recycle is at constant temperature and pressure to increase stability and repeatability of water cooling equipment and instrument cleaners and conditions or clean water. Angle use and back of application of cooling of water flow.
An uncommon open-loop controlled industrial refrigerator is an open tank or oil pan at which the temperature of the liquid is continuously circulating. The liquid comes from the tank and goes back to the tank through the pump crew. It is an adjustable constant temperature sensory liquid temperature and circulation cooler to maintain constant temperature tank.
One of the new developments in industrial chillers is air cooling, not the use of cooling water. In this case, the condenser of industrial water chiller does not have cooling and hot air refrigerant, but uses cooling water. This development allows for more than 15% reduction in energy demand in coolers due to the small area of surface water. In addition, the noise level can be greatly reduced with the permission of the fans.
Most industrial chillers use cooling media for refrigeration, but some simple technologies that rely on air or water include cooling coil flow that regulates temperature. Water is a commonly used coolant in refrigeration process, although cooling mixtures (mainly with coolant additives to enhance cooling water) are often used.
関連推奨品
-
加熱冷却サーキュレーターの展望
970企業の絶え間ない発展に伴い、洗濯機に使用されるマッチング機器として、メーカーのブランドとして機能する暖房冷却サーキュレーターは市場で繁栄し、その要求を絶えず加速させている。このような背景の下で、当社は、「...
詳細を見る -
半導体ウェハー温度制御における冷凍原理の説明
1267半導体ウェハー温度制御冷凍システムの運転では、ある作動流体の状態遷移を利用し、温度の低い熱源から必要な熱Q0を取り出し、熱Qkを...
詳細を見る -
Low-temperature cycle equipment operation importance description
1068The use of low-temperature cycle equipment is inseparable from its standard operation. LNEYA low-temperature cycle equipment will be shipped with the corresponding instruction manual, and users can know ahead of time when using it. The low tempera...
詳細を見る -
スクリーンレス冷凍庫のメンテナンス作業に関する分析
1385網戸外し冷凍庫は、工業用冷間加工で使用される機器の一種です。LNEYAスクリーン開閉式冷凍庫のメーカーは、スクリーン開閉式冷凍庫を長期間使用する場合は、メンテナンス作業が必要であることを皆に思い出させる...
詳細を見る