Shutdown method in the case of high-precision high-low temperature circulator failure
The high-precision high-low temperature circulator is one of the equipments used in the pharmaceutical and chemical industry to support various reactors. If users encounter an abnormal power outage during use, they should pay attention to operation to avoid causing failures.
1. The power switch should be turned off and the compressor’s suction valve and exhaust valve should be closed immediately. At the same time, the liquid supply valve should be closed to stop supplying liquid to the evaporator. Many produce wet compression.
If the cooling water of the equipment is interrupted suddenly, the power should be cut off immediately and the cooling water circulator stopped to avoid the condenser pressure being too high. Immediately after the compressor is stopped, the compressor’s suction and exhaust valves and related liquid supply valves should be closed, and the cause should be found to eliminate the fault and restart the water supply.
2. When a compressor needs to be stopped due to damage to a part of the compressor during operation, if the time permits, it can be operated as normal shutdown. If the situation is urgent, the power of the motor must be cut off, and the suction, exhaust and liquid supply valves should be closed.
3. If a fire in an adjacent building jeopardizes the safety of the high-precision high-low temperature circulator, the power should be cut off, and the exhaust valves of the accumulator, condenser, ammonia oil separator, and evaporator should be quickly opened to quickly open the emergency discharge The ammonia device and its water valve make the ammonia solution of the system concentrated to be discharged at the emergency ammonia discharge port, and are diluted by a large amount of water to prevent accidents caused by the spread of fire.
4. To protect the circulating water pump from running without water, please ensure that the water tank is filled with enough water before turning on, otherwise the water pump is easily damaged. When the water level of the water tank is below the green range of the water level gauge, the refrigeration capacity of the high-precision high-low temperature circulator will decrease slightly. Please ensure that the water level of the water tank is within the green range of the water level gauge. It is strictly forbidden to use a circulating pump for drainage. The air outlet on the high-precision high and low temperature circulator must be more than 1250px away from the obstacle, and the side air inlet must be more than 750px away from the obstacle. The power socket is in good contact and the ground wire is reliably grounded. The power supply voltage of Wuxi Guanya high-precision high-low temperature circulator must be consistent with the equipment’s power supply voltage, which will affect the safe operation of high-precision high-low temperature circulator.
The cooling and heating system of Wuxi Guanya LNEYA high-precision high-low temperature circulator supports customization. If users are more concerned about other safety devices, they can also customize the isolation and explosion-proof type, which is more reliable in use.
関連推奨品
-
Core Maintenance Points of Ten High and Low Temperature Test Chamber Manufacturers
1069According to many years’ production experience of high and low temperature test chamber in Wuxi Guanya, it is found that many users are not very familiar with the maintenance of high and low temperature test chamber. As one of the top ten manufact...
詳細を見る -
ベアリング低温処理装置の利点
1121超低温フリーザーの名前の一つはベアリング極低温処理装置です。無錫莞亜LNEYAの超低温フリーザーは、大容積比、大容量ベアリング容量設計、温度を設定することができます。
詳細を見る -
2021年度原子炉温度制御機器優秀サプライヤー」受賞
3043LNEYA was awarded the "2021 Excellent Supplier of Reactor Technology" by Corning, a Fortune 500 company in the United States. Since 2015, LNEYA has won this award for 7 consecutive years. Therefore, in the reactor manufacturing industry, we have ...
詳細を見る -
エア・コントロール・システムの清掃方法は?
1329国内の2つのタイプの社会の要求に応えるため、環境保護と保全の重要性がますます高まっている。そのため、製品の寿命を延ばすためには、やはり...
詳細を見る