単一反応釜の水冷式冷凍機の停止制御方法
The reaction kettle water cooled chiller has a wide range of accessories and equipment. In actual use, it needs to be provided with regular rest time. In order to maintain the stable performance of the refrigerator during long-term operation, it is necessary for the user to master the method of stopping the operation according to the actual use requirements, and to reduce the excessive wear of the equipment.
1. When it is necessary to shut down, first consider ensuring that the reactor freezer is within the shutdown range before performing all shutdown operations. In order to avoid the generation of high pressure, the user needs to close the suction stop valve to stop the operation of the compressor.
2. After completing the shutdown of the refrigerator compressor, it is necessary to operate the oil pump. Return the slide valve of the freezer to the 0-scale position so that the load reduction reaches zero. At this time, the oil pump will immediately stop all operations.
3. For the reaction kettle water cooled chiller, the operation of the water pump and cooling water tower needs to be stopped in the latter step. After stopping this type of equipment, the entire power supply can be turned off and the entire shutdown process can be completed. Ensure that the reactor water cooled chiller is in the shutdown state.
Precautions for reactor shutdown:
1. If the machine stops for a long time, special treatment is required. Including the condenser and the evaporator, the refrigerant needs to be completely pumped to the condenser, and at the same time all the water sources are discharged to avoid problems such as corrosion.
2. After the shutdown is completed, various accessories need to be carefully tested. The shutdown process is more particular, and the correct shutdown steps can prolong the service life of the equipment.
For the reactor freezer that has been shut down for a long period of time, careful testing is required to ensure that the equipment is kept away from various corrosive substances.
関連推奨品
-
チップテスト専用機TES-5シリーズ準備要領
955The TES-5 series for chip testing is used for electronic component testing. How to accurately detect the chip is very important. So, how much do you know about the test preparation for the TES-5 series for chip testing? Before starting the TES-5 s...
詳細を見る -
水冷式チラーと空冷式チラーの選択方法
1004現在、工業用冷水機は、石油化学工業、プラスチック工業、電子工業、真空コーティングなど、さまざまな産業に応用されている。しかし、工業用冷水機を購入する際、多くのエンタ...
詳細を見る -
新エネルギー自動車駆動モーター試験システムにおける凍結油の影響
1202新エネルギー車駆動モーター試験システムにおける冷凍機油の危険性は、凝縮温度と凝縮圧力を上昇させ、凝縮器の熱伝達を悪化させる。冷凍機油の油膜は、冷凍機油に混入する油によって生成されるため、冷凍機油の油膜を除去することはできません。
詳細を見る -
反応冷却に極低温冷凍機を使用するポイント
1108極低温冷凍機はチラー、極低温冷凍サーキュレーターとも呼ばれる。低温-110度の冷凍を実現する実験装置である。この種の装置は単流体冷凍機でよく使用される。
詳細を見る