What are the influences on the refrigeration factors of the enclosed explosion-proof chiller?
Check if it is the cause of the failure of the enclosed explosion-proof chiller. This selection must be accurate. If the model is not in place, the required cooling effect will not be achieved. It is recommended that the user will need it when purchasing the enclosed explosion-proof chiller. The cooling capacity and other parameters are provided to the chiller manufacturer, and professionals will select the model for you to achieve the required cooling effect.
The enclosed explosion-proof chiller has higher requirements for the working environment, because it is cooled by hot air circulation. If the ventilation effect of the installation workshop is not good, it will directly affect the cooling effect. There is more dust on the surface of the compressor, which leads to slow heat dissipation of the compressor and indirectly affects the cooling effect. There is leakage or shortage of refrigerant in the enclosed explosion-proof chiller, which leads to a decline in the cooling effect of the chiller. The accumulation of debris or sludge in the evaporator causes the flow rate to slow down, which affects the evaporation and condensation capacity and reduces the cooling effect.

The dust in the condenser of the enclosed explosion-proof chiller will affect the heat dissipation effect. The equipped unit is operating at full load, and the ambient temperature rises, resulting in insufficient cooling power and thus affecting the cooling effect.
Insufficient refrigerant, which is what we often call Freon, will also lead to poor cooling performance of the enclosed explosion-proof chiller. During the operation of the chiller, the liquid refrigerant in the evaporator continuously absorbs heat from the water and starts to evaporate. After the compressor is compressed and throttled by the expansion valve, it becomes a low-temperature and low-pressure refrigerant and enters the evaporator to continue. Circulation, if the use time is too long, the refrigerant will volatilize, which will affect the cooling effect.
When the filter of the enclosed explosion-proof chiller is blocked, it affects the heat exchange effect of the condenser, and the cooling effect of the whole machine is not good. It needs to be checked regularly and cleaned. When the filter is seriously clogged, it is recommended to replace the new filter drier.
関連推奨品
-
単一反応釜の水冷式冷凍機の停止制御方法
1292反応釜水冷式冷凍機には、さまざまな付属品や設備がある。実際の使用では、定期的な休息時間を設ける必要がある。長期運転中、冷凍機の安定した性能を維持するために、...
詳細を見る -
熱媒油二次循環システムにおける熱媒油の洗浄手順
1084熱媒油二次循環システムは、熱媒油を媒体として冷凍・加熱温度制御を行います。そして、使用者が熱媒体油二次循環システム内の熱媒体油を洗浄すると、熱媒体油二次循環システムは、熱媒体油二次循環システム内の熱媒体油を洗浄します。
詳細を見る -
-
超低温工業用冷蔵庫でのベアリングの冷間組立に関する説明書
983超低温工業用冷蔵庫の冷凍システムは、一般的にカスケード冷凍の作動原理を採用し、2つの完全密閉式コンプレッサーが高温コンプレッサーと低温コンプレッサーとして使用される。コンプレッサーの銅管は...
詳細を見る