What are the characteristics of the pressure of industrial water chillers
Industrial water chillers are one of the
most popular equipment in the machinery and equipment industry. For this
reason, the editor of LNEYA specially compiled relevant pressure instructions
to help everyone better understand industrial water chillers.
The reference value related to the pressure
resistance of industrial water coolers and piping system components refers to
the design given pressure related to the mechanical strength of the piping
components. The nominal pressure is generally expressed by PN. The nominal
pressure of the special chiller for the laboratory-the compressive strength of
the product at the reference temperature, expressed in PN, the unit: MPa, the
reference temperature: the reference temperature is different for different materials,
for example, the reference temperature of steel is 250°C, The
nominal pressure is 1.0Mpa, which is recorded as: PN 1.0 Mpa.
The working pressure of the industrial
water chiller refers to the large pressure required for the operation of the
pipeline system according to the high working temperature of the pipeline
conveyed by the medium at all levels. The working pressure is generally
expressed in Pt.
The design pressure of an industrial water
chiller refers to the large instantaneous pressure that the water supply piping
system acts on the inner wall of the pipe. Generally, the sum of the working
pressure and the residual water hammer pressure is used, and the design
pressure is generally expressed in Pe.
The test pressure of an industrial water
cooler refers to the pressure that the pipeline, container or equipment must
reach for the pressure resistance and air tightness test requirements. The test
pressure is generally expressed by Ps.
The nominal pressure of industrial water
chillers is for the convenience of design, manufacture and use, and is a
nominal pressure artificially specified. The unit of this nominal pressure is
actually the pressure, and the pressure is the common name in Chinese, and the
unit is “Pa” instead of “N”. The nominal pressure of the
pressure vessel refers to the nominal pressure of the pressure vessel flange.
The nominal pressure of the pressure vessel flange is generally divided into 7
levels, namely 0.25, 0.60, 1.00, 1.60, 2.50, 4.00, 6.40MPa.
要約する
Generally speaking, the pressure of
industrial water chillers can be divided into: test pressure>nominal
pressure>design pressure>working pressure. If you have any other
questions, you can consult us and send an email to sales@lneya.com
関連推奨品
-
チップ製造の高温・低温エージング試験室の機能は?
1005現在、チップ・ウェーハ製造業界はかつてない挑戦と変化に直面している。技術だけでなく、生産量もこの業界では常に懸念事項となっている。チップの誕生には多くの工程が必要であることは誰もが知っている。
詳細を見る -
貯水タンクを冷却するために、なぜチラーを設置する必要があるのですか?
1001貯水タンクを冷却するためにチラーを構成する主な理由は、以下の側面に関連している:温度制御:空調システム、化学プロセスなど、多くの産業・商業用途では、水貯蔵タンクを冷却するためにチラーを使用します。
詳細を見る -
化学材料の製造工程のための低温冷却のスリラー
8851.温度に敏感な反応は、特に高分子材料、医薬中間体、その他のファインケミカルの合成において、温度に非常に敏感な多くの化学反応を制御する。低温...
詳細を見る -
Various reactors and materials use PLC temperature control system
1246The PLC temperature control system is used for the lifting and constant temperature control of glass reactors, metal reactors and bioreactors, especially for heat exothermic control in the reaction process. The heat transfer oil in the jacket of t...
詳細を見る