原子炉水冷チラー停止時不使用時の注意事項
When the reactor water-cooled chiller has
complete accessories, in actual use, it is necessary to provide it with regular
rest time. In order to maintain stable performance of the chiller during
long-term operation, users need to master the method of stopping operation
according to actual use requirements to reduce excessive wear and tear of the
equipment.
1. When it is necessary to shut down, first
consider ensuring that the reactor water-cooled chiller is within the shutdown
range, and then perform all shutdown operations. In order to avoid the
generation of high pressure, the user needs to close the suction shut-off valve
and stop the compressor.
2. After the compressor of the chiller is
shut down, the oil pump needs to be operated. Return the slide valve of the
freezer to the 0 mark position, so that the load reduction reaches zero. At
this time, the oil pump will immediately stop all operations.
3. For the reactor water-cooled chiller,
the operation of the water pump and the cooling water tower needs to be stopped
in the later stage. After stopping such devices, you can turn off the entire
power supply and complete the entire shutdown process. Ensure that the
reactor’s water-cooled chiller is in a shutdown state.
Precautions for the shutdown of the
water-cooled chiller of the reactor:
1. If the machine is shut down for a long
time, special treatment is required. Including the condenser and the
evaporator, all refrigerants need to be pumped into the condenser, and all
water sources must be discharged at the same time to avoid corrosion and other
problems.
2. After the shutdown is completed, various
accessories need to be carefully tested. The shutdown process is special, and
the correct shutdown procedure can prolong the service life of the equipment.
For long-term closed reactor water-cooled
chillers, careful testing is required to ensure that the equipment is kept away
from various corrosive substances. When our LNEYA equipment is delivered to the
user, there will be a detailed instructions for use. The content includes the
handling methods and precautions of the water-cooled water chiller at the use
site, in order to reduce equipment failure and protect the user For the
efficiency of use, please contact us sales@lneya.com for details.
関連推奨品
-
-
ワークピースの冷凍に使用される工業用冷蔵庫はどのようなモデルですか?
995ワーク・フリーザーとは-工業用冷間収縮組立技術-延命、金属冷間処理とは、金属または合金のワークをある種の媒体に入れ、適切な温度まで加熱し、この温度で一定時間保持することである。
詳細を見る -
原子炉の冷凍・加熱システム用熱媒油の選択
1118化学工業において、反応器は一般的に使用される容器であり、温度制御は主な制御量である。反応器の加熱と冷凍サイクル設備は製品の品質を確保する重要な要素である。反応器...
詳細を見る -
新エネルギー自動車用パワーバッテリー試験システムにおける共通故障の分析
961新エネルギー車パワーバッテリーパックが漏れた場合、一般的な故障の顕在化モード:メーターOKランプが点灯しない、メーターは、電源システム、高電圧システムの漏れの障害をチェックするように促し、バッテリーパックとバッテリーを切断する。
詳細を見る