冷凍・暖房サイクル機器の配管詳細説明
When the refrigeration and heating cycle equipment is in operation, the user will find that whether or not the fully enclosed pipeline affects the overall performance. The LNEYA refrigeration and heating cycle equipment adopts a fully enclosed cycle pipeline, and there is no oil mist and water vapor during high and low temperature operation, which is continuously improved. Operational efficiency, so what is important in piping design?

The refrigeration and heating cycle equipment adopts a fully enclosed pipeline design and a high-efficiency plate heat exchanger, which reduces the demand for heat transfer fluid while increasing the heat utilization rate of the system to achieve rapid temperature rise and fall. The heat transfer medium is in a closed system with an expansion vessel. The heat transfer medium in the expansion vessel does not participate in the circulation. Whether it is high or low temperature, the temperature of the expansion tank is from room temperature to 60 degrees, which can reduce the absorption of moisture and volatilization of the heat transfer medium during operation. risk.
The refrigeration and heating cycle equipment should keep the entire system of the refrigeration and heating cycle equipment group clean after installing the compressor welding pipes to avoid welding slag and other impurities in the refrigeration and heating cycle equipment system, causing serious malfunctions during compressor operation. Vibration is unavoidable during operation. In order to reduce the vibration of the pipeline, it is recommended to use copper pipes as suction and exhaust pipes. In this way, when the compressor is running normally, the copper pipe in the pipeline can reduce the vibration. If steel pipes are to be used for the piping in the system, proper welding techniques are very important to avoid stress in the piping system. These internal stresses will cause resonance and noise, which will reduce the service life of the compressor.
After the refrigeration and heating cycle equipment is welded, the oxidized impurities and debris generated by the welding of the pipeline should be removed in time. If these impurities enter the compressor, it may cause the oil filter to block and make the lubrication system and the capacity adjustment system fail. If the suction and discharge flanges of the compressor of the refrigeration heating cycle equipment are made of cast steel, they can be directly welded to the pipeline. After welding, it should be cooled in the atmosphere, and cooling with water is prohibited.
LNEYA refrigeration and heating cycle equipment is different from other manufacturers in terms of overall performance. Different manufacturers have different prices and configurations, so you need to pay attention to the price of one product.
関連推奨品
-
Storage tank cooling refrigeration chiller
828Tank cooling chiller is a device specifically used to cool materials in a tank to ensure that the materials in the tank are stored within a suitable temperature range to maintain the quality and performance of the materials. This type of c...
詳細を見る -
The Analysis Of Ultra Low Freezer’S Price
1199What are the characteristics and functions of ultra low freezer:1. Ultra low freezer can prevent the precision of machine equipment from being influenced by the change of oil temperature in the process of operation. 2. Ultra low freezer can preven...
詳細を見る -
What Are the Differences Between Low Temperature Test Chamber and Refrigeration?
1251The low temperature test chamber, you can see by its name, probably means to do cryogenic test. It is more important in our refrigeration equipment. The small series of low temperature test chamber tells you that the refrigeration of low temperatu...
詳細を見る -
API China [A1A20-2] welcomes new and old customers!
1238API China, as a long-standing and large-scale exhibition in China's industrial field, has promoted and witnessed the development and growth of the pharmaceutical industry, and has also been accompanied by generations of Chinese pharmaceutical peop...
詳細を見る