マイナス30℃におけるエチレングリコールチラーの設定・運転方法の紹介
The minus 30 degree ethylene glycol chiller is a single-fluid low-temperature refrigeration unit with compressor refrigeration. How should the user set it better when operating it?

1. Automatic logout time
Automatic logout means that when a user has an account and is logged in, the logged-in account will be automatically logged out if there is no operation for a long time.
The working principle of the minus 30℃ethylene glycol chiller is to start timing from the touch screen without operation, and automatically log out and log in when the set value is reached. Each time the touch screen is operated, the timer will be reset to zero. If this parameter has a power-off hold function, the user’s parameters will be retained next time.
2. Language selection
The operating system of the minus 30℃ ethylene glycol chiller currently only supports 2 languages, English and Simplified Chinese. Users can choose according to their language strengths. The language selection has a power-off hold function, that is, the language will be continued at the next power-on. Of course, other languages can also be customized.
3. Buzzer touch response
The buzzer touch response means that when the touch screen is touched, there will be a “di~” sound on the touch screen to prove whether the user’s touch is valid. Users of -30℃ ethylene glycol chiller can cancel this function, and can also prolong the sounding time of this “di~”. Changes to the sound duration require a restart to take effect. This time unit is ms, which is not very accurate due to the limitation of the touch screen clock precision and the processing speed of the processor.
4. Buzzer feedback
Feedback means that the touch screen will produce a pulsed beep sound of “Di Di Di ~”. Because the buzzer power is limited, the sound is not loud, and the volume of the sound cannot be adjusted. If the user of the -30°C glycol chiller intends to use this function and feels that the sound of this function is not enough, an external buzzer can be connected, as explained above.
5. Automatic backlight time
Automatic backlight means that the touch screen will automatically light up when the touch screen is touched, and it will automatically turn off when it is not used for a long time. The touch screen will automatically turn off when it reaches the set time. If it is set to off, the touch screen will always be on. It will have a slight impact on the life of the touch screen of the ethylene glycol refrigerator at minus 30 degrees.
6. System time
The user can modify the system time of the minus 30 degree ethylene glycol refrigerator here. Guanya recommends that the user should not deviate too much from the actual time when modifying, otherwise it will have the possibility of affecting the use of the device. Please do not set a non-existent date (eg: February 30th), which may cause confusion in the device program.
7. Store information
Data logging used for the operation of a -30°C glycol chiller, Users can check the remaining storage space of the touch screen here, and can clean up the disk when the space is low.
8. Temperature save cycle
The touch screen of the minus 30 degree ethylene glycol refrigerator is powered on as a symbol, and it is recorded and saved when it is powered on. Although it will lead to a large amount of useless data, but considering that the storage space is basically sufficient and some users’ requirements for temperature data, the temperature storage cycle is designed. Here you can modify the save cycle of temperature data.
The refrigeration temperature range of minus 30℃ ethylene glycol chiller is from -150℃to -5℃, which can meet the needs of different refrigeration temperatures. It is widely used in low temperature reaction fields in chemical, pharmaceutical, biochemical and other industries.
関連推奨品
-
特殊環境用コンポーネント・テスター
1628With the continuous development of the semiconductor industry, component component testing has been widely used in components in the fields of industry, scientific research, pharmaceuticals, and chemical industry. At present, there are quite a few...
詳細を見る -
熱衝撃試験チャンバー冷却方式
1269つの一体型熱衝撃試験機は、ユーザーの要求に応じて設計・製造されます。これらの試験機は、高温または低温環境での衝撃試験や高温・低温環境での衝撃試験に適しています。
詳細を見る -
How to Solve the Problem that Water 10hp Refrigerator Can’t Produce Water
1091Wuxi guanya has cold plate freezer for sale for the industrial cold treatment.Well,how to solve the problem of water outlet fault of 10hp cold plate freezer?Therefore,I have sorted out the relevant solutions for the water outlet fault of 10hp cold...
詳細を見る -
バイオ医薬品プロセスで冷却水システムを必要とする機器は?
852バイオ医薬品プロセスでは、多くの重要な機器や装置が、その正常な動作とプロセス温度制御を維持するために冷却水システムを必要とします。以下は、冷却水を必要とする一般的な機器の種類です。
詳細を見る