Maintenance knowledge of 12HP (8.9kW) low temperature chiller
The user can arrange the operator to learn about the daily maintenance knowledge of the 12HP (8.9kW) low temperature chiller after purchase. It can not only improve the company’s product quality, improve production efficiency, but also extend the service life of the 12HP (8.9kW) low-temperature chiller by using the knowledge learned.

1. In the initial operation of the 12HP (8.9kW) 低温チラー, the oil level, oil return and oil cleanliness of the compressor should be observed frequently. If the oil is dirty or the oil level drops, it should be replaced or added in time to avoid poor lubrication and affect refrigeration. machine is running.
2. For air-cooled: the air-cooler should be cleaned frequently to maintain a good heat exchange state, and the condenser should be checked frequently for scaling problems, and the scale should be removed in time.
3. For water-cooled: Always check the turbidity of the cooling water, if the cooling water is too dirty, it needs to be replaced, whether the water pump is working normally, whether the valve switch is effective, whether the cooling water tower and the fan are normal.
4. For the air-cooled evaporator: it is necessary to check the defrosting situation frequently. Whether the defrosting is timely and effective will affect the cooling effect and cause the refrigeration system to return to liquid.
5. Always observe the compressor running status of the 12HP (8.9kW) low-temperature chiller, check its exhaust temperature, and pay special attention to the running status of the system when operating in a seasonal change, and adjust the liquid supply and condensing temperature of the system in time.
6. Carefully listen to the running sound of the compressor, cooling tower, water pump or condenser fan, find out and deal with it in time, and check the vibration of the compressor, exhaust pipe and water pump at the same time.
7. After 30 days of operation, the refrigerating oil and drying filter should be replaced once, and after half a year of operation (depending on the actual situation). For systems with higher cleanliness, the refrigeration oil and filter drier should be replaced after six months of operation.
Our LNEYA is a professional chiller manufacturer, our customers are located in Europe, America and Southeast Asia. For the 12HP (8.9kW) low temperature chiller, you can contact us if you have any questions.
関連推奨品
-
極低温冷凍機におけるクライオポンプの設置ポイント
1243クライオポンプは極低温冷凍機の構造上、必要不可欠なものです。低温冷凍庫メーカーであるLNEYA社は、クライオポンプを設置する際には、その要件に従って運転する必要があることを皆様にお伝えしています。設置の容易さ
詳細を見る -
New energy testing method and application case of temperature simulation thermostat
939LNEYA new energy vehicle battery high and low temperature cycle test is one of the most widely used equipment in modern vehicle battery testing. Lithium battery is one of the more common batteries. What should be paid attention to when using it? ...
詳細を見る -
高温と低温の冷却サーキュレーターの設置に注意すること
1302高温・低温冷却サーキュレーターは、正しく設置されてこそ、より良い運転が可能になる。設置の際に設置が適切でないと、高温・低温冷却サーキュレーターはある種のハ...
詳細を見る -
超低温冷凍庫の戻り油問題を解決するには?
1488超低温フリーザーは長期間使用すると故障するため、油戻りが発生した場合は特に注意が必要である。超低温フリーザーでは、オイルの戻りがスムーズでないため、大量の潤滑...
詳細を見る