原子炉はどこで使用されるのか?原子炉の温度制御システムは?
Generally, non professionals should be confused about the reactor.
The reactor is composed of reactor body, reactor cover, jacket, agitator, transmission device, shaft seal device, support, etc. It is generally understood as a container with physical or chemical reactions. Through the structural design and parameter configuration of the container, the functions of heating and mixing, hydrolysis, neutralization, distillation, evaporation, crystallization, storage, hydrogenation, alkylation, polymerization, constant temperature reaction, cooling and low and high speed mixing required by the process can be realized.
The application scope and scenario of the reactor mainly include the following eight areas: 1. Food agriculture; 2. University test; 3. Biochemical pharmacy; 4. Gold refining industry; 5. Scientific experiments; 6. Bioengineering; 7. Industrial factory; 8. New material industry.
The temperature control of the reaction kettle is divided into two types: rising temperature and cooling temperature (depending on whether the inside is exothermic reaction or endothermic). Steam, molten salt or other heating media are used for heating, while cooling is generally cooling water or other media. Whether heating or cooling, heating or cooling media flow control is used, manually open and close the valve, or use automatic control to control heating The control valve of cooling medium regulates the flow to control.
The whole liquid circulation is a totally closed system.
1. Speed block for temperature rising and cooling, controlling chemical reaction system
2. The heat conduction medium will not absorb water vapor at low temperature
3. The heat conduction medium will not be oxidized, discolored, or browning
No oil mist is generated at high temperature.
4. Thermodynamic changes of the fast response system, whether it is a severe endothermic or exothermic reaction, will not have temperature control hysteresis.
5. A heat conduction medium can be used for low temperature and high temperature, and can be used in the temperature range of – 120 ℃ – 350 ℃.
関連推奨品
-
Vocs exhaust gas condensation recovery unit refrigerant charging instructions
1090In the vocs exhaust gas condensation recovery process, the refrigerant is able to affect the operation of the vocs exhaust gas condensation recovery process, vocs exhaust gas condensation recovery treatment professional manufacturers reminded that...
詳細を見る -
冷凍加熱温度制御システムの典型的なアプリケーション
888LNEYA 高圧反応釜の冷熱源の動的恒温制御、二重層ガラス反応釜の動的恒温制御、二重層反応器の冷熱源の動的恒温制御。マイクロ...
詳細を見る -
企業が加熱クーラーを使用する際のいくつかの大きな考慮事項
1251上記の企業に加えて、冷蔵庫の始動・停止、スイッチ、修理・メンテナンスの責任者を手配する必要がある。企業における冷蔵庫の使用に関する注意事項は以下の通り。
詳細を見る -
超低温フリーザーのブランドヒント
874超低温フリーザーというと、超低温ということは技術がより難しくなるということで、心配になる人が大多数だろう。他の冷媒プラントと比較して、超低温フリーザーの選択は...
詳細を見る