Automotive antifreeze test test temperature control system

When it comes to car antifreeze, we all know that its main function is to prevent the coolant from freezing and cracking the radiator and freezing the engine cylinder block or cover when we stop in the cold winter. Make the cooling system in the best working condition and ensure the normal working temperature of the engine.
The freezing point of water is 0°C, and ordinary antifreeze can reach -40°C, while high-quality antifreeze should be able to reach about -60°C, and the antifreeze has a high boiling point. The boiling point of water is 100 °C, and the boiling point of high-quality antifreeze coolant is usually 110 °C above zero, so it is more difficult to boil antifreeze coolant than water in summer.
Antifreeze detection items: freezing point detection, antifreeze detection, low temperature stability, thermal stability, etc. In these tests, temperature control is left off. When the testing organization carries out these testing items, it is necessary to ensure the constant temperature environment, cooling and heating temperature difference, time and so on during the testing process.
LNEYA automotive antifreeze cooling, heating, temperature control and flow system KRY series equipment is the temperature and flow control equipment required by this type of organization. The temperature range is minus 40 degrees to 100 degrees. The temperature changes during the test are visualized, and the data storage and report analysis can be exported for the convenience of the technicians of the testing organization.
The temperature test mentioned here is the high temperature endurance test and the low temperature endurance test. The low temperature endurance test mainly tests the cold start performance, the charging and discharging ability, the charging and discharging ability of the battery pack at high temperature, the cooling function of the battery pack and the overheat protection strategy.
Our LNEYA KRY series cooling, heating, temperature and flow control systems are the best choice for testing institutions, saving costs and increasing the efficiency and accuracy of testing.
関連推奨品
-
冷凍・暖房・温度制御システムから始まる製品の多様化開発
1015無錫観亜冷凍技術有限公司は2006年に設立されました。それは冷凍および暖房装置のスタジオをセットアップした。2007年、第一世代の冷凍・暖房サイクルを発表し、「LNEYA」の商標を登録した。2008年、LNEYAを設立。
詳細を見る -
-
マイナス80度の超低温フリーザーの使い方
1191The machine must be tested before usage (or before it is energized again) in the following conditions: when ultra low temperature freezer is first used in ultra low temperature freezer minus 80 degrees, or after the ultra low temperature freezer i...
詳細を見る -
10Lリアクター温度制御装置
83710L反応器温度制御装置、別名油浴機、正確に反応器内の温度を制御するために使用される装置であり、通常、熱伝達油(熱伝達流体としても知られている)を介して、加熱を達成するために...
詳細を見る