The reason why the cooling thermostat Chiller suddenly fails to start

If there are any unexpected situations during the use of the cooling thermostat Chiller, it is important to promptly identify the specific reasons before resolving them, in order to effectively address various issues. For example, what is the reason why the cooling thermostat Chiller suddenly fails to start during operation?
One、 The reason why the cooling thermostat Chiller cannot start
1. The main reason is that during the operation of the system, the pressure at the equipment inlet is low, which cannot meet the basic operating conditions, leading to the problem of not being able to start.
2. According to the instructions for the configuration of the refrigeration thermostat Chiller, it can be understood that it is mainly caused by the idle water pump and other reasons. As long as the air in each system of the refrigeration thermostat Chiller is released, it can meet the suitable operating environment and achieve the purpose of starting the refrigeration thermostat Chiller.
3. The issue of stress. After experiencing varying degrees of startup difficulties, it is necessary to complete the maintenance of the refrigeration thermostat Chiller according to actual needs.
4. To ensure smooth operation, it is necessary to effectively control the inlet and outlet of the water pump during the use of the refrigeration thermostat Chiller. As the air is continuously eliminated, any malfunctions that cannot be started can be resolved.
Two、 Handling methods for encountering high-voltage faults
1. Due to insufficient cooling water flow, the rated water flow cannot be reached. The main manifestation is that the pressure difference between the inlet and outlet water of the unit decreases and the temperature difference increases. The reason for insufficient water flow is due to a lack of water or air in the system. The solution is to install an exhaust valve at a high position in the pipeline for exhaust; If the pipeline filter is blocked or too fine, and the permeability is limited, a suitable filter should be selected and the filter screen should be cleaned regularly; The selection of water pumps is relatively small and not compatible with the system. Excessive refrigerant charge.
2. This situation usually occurs after maintenance, manifested as high suction and exhaust pressure, balance pressure, and high operating current of the compressor. It should be deflated under rated operating conditions based on suction and exhaust pressure, balance pressure, and operating current until normal, so it is still necessary to regularly check.
関連推奨品
-
Description of heat sink characteristics in chip temperature control
1297With the continuous development of electronic chips, its heat dissipation technology is also advancing. LNEYA chip temperature control technology is continuously promoted along with chip test equipment. The development trend of modern computer chi...
詳細を見る -
エチレングリコール・チラーが重合反応やカップリング反応に使用できる理由
9061.重合加熱一般的に、重合反応の原料はいくつかの可燃性溶剤であり、急速に加熱すると、局所温度が高くなりすぎて事故を引き起こす可能性がある。重合反応にはそれぞれ適切な反応...
詳細を見る -
油圧式冷凍機 工業用/実験用冷凍機?
824油圧式冷凍機は、工業用冷凍機や実験室用冷凍機と直接的に同等というわけではないが、機能的には一定の関連性と重複性がある。いずれも冷却効果を得るための装置である。主な違いは、その用途にある。
詳細を見る -
産業用冷凍機の四方弁の交換方法は?
889産業用冷凍機の四方弁は、長期間使用すると交換が必要になりますが、どのように交換するのでしょうか?工業用冷凍機の四方弁を交換する場合、まず、四方弁を接続している接続パイプを取り外す必要があります。
詳細を見る