駅全体を検索

Thermal oil heating system

  • UST series adopt the high-temperature cooling process to achieve a temperature drop of 300℃ to 50℃ at a very fast speed.
  • A fully enclosed circulating system
  • Large heat exchange area, the heating and cooling rates are very fast
  • There is no evaporation of oil mist at high temperatures
  • PLC controller, five programs can be compiled, and each program can contain 40 steps.
  • The maximum cooling power is 95kW (UST-A9530)

Lneya’s UST series is a high-end model of heating circulators with a 熱油暖房システム. By adopting the feedforward PID algorithm and the model-free self-constructed tree algorithm, the temperature lag can be reduced. There are two modes: material temperature control and equipment outlet temperature control. You can freely choose either one. The UST series heating circulator utilizes three-point sampling (heat-conducting medium inlet temperature, outlet temperature and reactor material temperature) to send feedback on temperature. The UST series can not only control the temperature of the heat transfer medium but also the temperature of the reaction material.

Thermal oil heating system

RT10°C

lowest

300°C

Highest

±0.5°C

温度制御精度


モデル UST-5530 UST-5530W UST-7530 UST-7530W UST-A1030 UST-A1030W UST-A1530 UST-A1530W UST-A2530 UST-A2530W UST-A3830  UST-A3830W UST-A6030 UST-A6030W UST-A9530  UST-A9530W
Temp range RT+10℃~+300℃
Medium temp acccuracy ±0.5℃ ±1℃
Material temp accuracy ±1℃
暖房能力 kW 5.5 7.5 10 15 25 38 60 95
冷却
 容量
300 ℃ 5.5 7.5 10 15 25 38 60 95
200 ℃ 5.5 7.5 10 15 25 38 60 95
100 ℃ 4 5 7 12 20 30 48 76
65 ℃ 1.8 2.2 3 5 8.5 12 19 30
循環ポンプ
max L/min bar
35 50 50 110 150 200 250 400
2 2 2 2.5 2.5 2.5 2.5 2.5
Connection siz ZG3/4 ZG3/4 ZG3/4 ゼットジーワン DN32 PN10 DN40 PN10 DN40 PN10 DN50 PN10
寸法cm 40*70*130 45*70*160 40*70*160 70*100*175 70*100*175 80*120*185 150*100*185 200*145*205
Power MAX
380V 50HZ
7kW 9kW 12kW 17kW 28kW 41kW 65kW 96kW

Heat apparatus: provide a heat source and convert electrical energy into thermal energy, and heat the heat-conducting medium.


Circulating Pump: the driving heat-conducting medium circulates within the system to ensure that the heat is uniformly transferred to the target equipment (such as reaction vessels, microchannel reactors, etc.). The circulating pump is resistant to high temperature and corrosion, and its flow rate can be adjusted.

産業用/研究室用加熱システムが見つからない場合は、チラーの詳細と価格について今すぐお問い合わせください。

When selecting the model, the following parameters need to be considered:
Key parameters, typical model examples, applicable scenarios, heating power, cooling capacity, pressure and flow rate. If you need rapid cooling from 300℃ high temperature, UST-A series(such as UST-A2530) is a the best choice. If only moderate and low-temperature control is needed, UST-5530 or UST-7530 is more economical.

*
*
提出......。
無事に提出された!
送信に失敗しました!後で再試行してください
電子メールのエラー!
電話エラー!

下記のQRコードからアカウントマネージャーを追加してください