SUNDIZ可変周波数シリーズ冷却暖房システム
アプリケーション
Compared with SUNDI refrigeration system, the circulation system adopts variable frequency control, which saves more than 20% energy, reduces noise by more than 5 decibels, and has a small starting current compared to old products.
By increasing the frequency, the refrigeration power is increased and the cooling rate is improved by frequency conversion control of the circulation pump.
製品の特徴
製品パラメーター
SUNDIZ -45℃~250℃
モデル | スンディズ4-3 SUNDIZ4-3W |
スンディズ4-5 SUNDIZ4-5W |
SUNDIZ4-10 SUNDIZ4-10W |
SUNDIZ4-15W | SUNDIZ4-20W | SUNDIZ4-30W | |
温度範囲 | -45℃~250℃ | ||||||
暖房能力 | 5.5kW | 7.5kW | 15kW | 25kW | 38kW | 60kW | |
冷却能力 kW | 250℃ | 5.5kW | 7.5kW | 15kW | 25kW | 38kW | 60kW |
20℃ | 5.5kW | 7.5kW | 15 kW | 25kW | 38kW | 60kW | |
-15℃ | 2.3kW | 3.6kW | 7.5 kW | 11kW | 15kW | 33kW | |
-35℃ | 0.9kW | 1.5kW | 3.3 kW | 5kW | 6.5kW | 10kW | |
中程度の温度制御精度 | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | |
プロセス温度制御精度 | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | |
ポンプ流量 最大圧力 | 50L/分 | 50L/分 | 100L/分 | 150L/分 | 250L/分 | 400L/分 | |
2バール | 2バール | 2バール | 2.5バール | 2.5バール | 2.5バール | ||
冷媒 | R-404A / R507C オプション R448 | ||||||
インターフェースサイズ | G3/4 | G3/4 | G1 | DN32 PN10 | DN40 PN10 | DN50 PN10 |
SUNDIZ -80℃~250℃
モデル | SUNDIZ8-3W | SUNDIZ8-4W | SUNDIZ8-6W | SUNDIZ8-10W | SUNDIZ8-15W | |
温度範囲 | -80℃~250℃ | |||||
暖房能力 | 3.5kW | 5.5kW | 7.5kW | 10kW | 15kW | |
冷却能力 kW | 250℃ | 3.5kW | 5.5kW | 7.5kW | 15 kW | 20kW |
20℃ | 3.5kW | 5.5kW | 7.5 kW | 15kW | 20kW | |
-60℃ | 1.3kW | 1.8kW | 3 kW | 5.5kW | 8kW | |
-75℃ | 0.4kW | 0.6kW | 1 kW | 1.8kW | 2.7kW | |
中程度の温度制御精度 | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | |
プロセス温度制御精度 | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | |
ポンプ流量 最大圧力 | 35L/分 | 50L/分 | 100L/分 | 150L/分 | 250L/分 | |
2バール | 2バール | 2バール | 2.5バール | 2.5バール | ||
冷媒 | R-404A / R508B |
Common Configuration
システム圧力表示 | 冷凍システムと循環システムの圧力は圧力センサーによって検出され、タッチスクリーンに表示される。 | ||||
コントローラー | Siemens S7-1200 PLC, fuzzy PID control algorithm, equipped with process dynamic control algorithm | ||||
温度制御 | Thermal medium outlet temperature control mode, external temperature sensor: (PT100 or 4-20mA or communication given) control mode (process dynamic control algorithm) |
||||
プログラマブル | 25 programs, each program can edit 85 steps | ||||
通信プロトコル | Ethernet interface TCP/IP protocol, RS485 interface, MODBUS protocol | ||||
Internal temp feedback | Equipment thermal conductivity medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, compressor suction temperature, cooling water temperature (for water-cooled equipment) |
||||
External temp feedback | Pt100 or 4-20mA or communication given | ||||
During cascade control Temp difference control function |
The temp difference between the outlet temp of the thermal oil and the external temp sensor can be set and controlled The temp difference between the inlet and outlet of the equipment can be set and controlled to ensure system safety |
||||
Closed circulation システム |
The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature. |
||||
暖房 | システムの最大暖房出力パワーを指す(各モデルによる) ヒーターは、加熱システムの安全性を確保するために、三重の保護と独立した温度リミッターを持っています; Using a voltage regulator to control the heating output and reduce the output current of the heater during process temperature control |
||||
External circulation Flow pressure | ブランド磁気ドライブ可変周波数ポンプ | ||||
コンプレッサー | Emerson, Mitsubishi and other variable frequency compressors | ||||
周波数変換器 | Famous brands such as ABB | ||||
蒸発器 | 316L Plate Heat Exchanger | ||||
冷凍アクセサリー | Danfoss/Emerson accessories (dry filters, oil separators, high and low pressure protectors, expansion valves) | ||||
操作パネル | LNEYAカスタマイズされた7インチカラータッチスクリーン、温度カーブ表示。 | ||||
安全保護 | Multiple self-diagnosis function; freezer overload protection; high/low pressure switch; overload relay, thermal protection device etc | ||||
水冷コンデンサー | プレート式熱交換器 | ||||
シェル素材 | 冷間圧延シート(標準色7035) | ||||
パワー | 380v 50hz/460v 60hz |
動作原理

超高温冷却技術は、300℃の高温から直接冷却することができる[膨張室内の熱伝導媒体のみが空気中の酸素と接触するため(膨張タンクの温度は常温から60℃の間)、熱伝導媒体が酸化して空気中の水分を吸収する危険性を低減することができる。高温時には熱伝導媒体が蒸発することがなく、-80℃~190℃、-70℃~220℃、-88℃~170℃、-55℃~250℃、-30℃~300℃の連続温度制御が無加圧で実現できる。
カラースクリーンコントロール

1.すべての種類のプロセス制御温度を表示します。
2.膨張容器内の熱伝導媒体の液面を示す。
3.冷凍システムの作動を示す表示。
4.ヒーターが作動していることを示す。
5.循環ポンプの作動を示す表示。
6.温度制御(材料温度制御パターン、熱伝導中温制御)を表示します。
7.温度上限、下限制御を設定できる。
8.ジャケットとリアクターの温度差を設定できる。
9.空になったら液体を追加するアラームを表示します。
10.冷凍コンプレッサーは、手動または自動で作動するように設定できる。
Customized solutions to meet your temperature process needs
CUSTOM CHILLER SIZES
ポータブル、コンパクト、大型、小型の冷凍機にかかわらず、お客様のご要望に応じてカスタム設計いたします。何トンのスリラーが必要でも、私達は最もよい解決を作成してもいいです。
CUSTOM CHILLER TYPES
空冷式、水冷式、蒸発凝縮式など、様々な冷凍タイプのチラーを提供しています。冷凍コンプレッサーの種類にかかわらず、お客様のご要望に応じて設計いたします。
CUSTOM TEMPERATURE RANGES
当社は-150℃から+350℃までの温度に対応するカスタムソリューションを作成することができます。特定の産業向けのカスタム温度範囲
CUSTOM CHILLER VOLTAGE
あなたの必要性に従ってスリラーの電圧および段階をカスタマイズして下さい。任意 110V/60HZ、220V/60HZ、380V/50HZ、220V/50HZ、400V/50HZ、460V/60HZ、440V~480V/60HZ、等。
温度制御サプライヤーとしてneyaを選ぶ理由
経験年数
顧客満足度
m² 生産面積
特許技術
LNEYA工場訪問